ArticlePhysical and engineering sciences in medicine2023

Assessment of thoracic spinal curvatures in static postures using spatially tracked 3D ultrasound volumes: a proof-of-concept study.

Laura Meszaros-Beller, Maria Antico, Davide Fontanarosa, Peter Pivonka

Open access · hybridFull text read
In one paragraph

Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Laura Meszaros-BellerSchool of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia. l2.meszaros@qut.edu.au.ORCID http://orcid.org/0000-0002-5032-3997
Maria AnticoCentre for Biomedical Technologies, Queensland University of Technology, Brisbane, Australia.
Davide FontanarosaCentre for Biomedical Technologies, Queensland University of Technology, Brisbane, Australia.
Peter PivonkaSchool of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia.
Queensland University of Technology · AUCommonwealth Scientific and Industrial Research Organisation · AU

Funding

Queensland University of Technology (QUT) Clayton Adam Florence Wilson Award
6 · The paper itself

Abstract

The assessment of spinal posture is a difficult endeavour given the lack of identifiable bony landmarks for placement of skin markers. Moreover, potentially significant soft tissue artefacts along the spine further affect the accuracy of marker-based approaches. The objective of this proof-of-concept study was to develop an experimental framework to assess spinal postures by using three-dimensional (3D) ultrasound (US) imaging. A phantom spine model immersed in water was scanned using 3D US in a neutral and two curved postures mimicking a forward flexion in the sagittal plane while the US probe was localised by three electromagnetic tracking sensors attached to the probe head. The obtained anatomical 'coarse' registrations were further refined using an automatic registration algorithm and validated by an experienced sonographer. Spinal landmarks were selected in the US images and validated against magnetic resonance imaging data of the same phantom through image registration. Their position was then related to the location of the tracking sensors identified in the acquired US volumes, enabling the localisation of landmarks in the global coordinate system of the tracking device. Results of this study show that localised 3D US enables US-based anatomical reconstructions comparable to clinical standards and the identification of spinal landmarks in different postures of the spine. The accuracy in sensor identification was 0.49 mm on average while the intra- and inter-observer reliability in sensor identification was strongly correlated with a maximum deviation of 0.8 mm. Mapping of landmarks had a small relative distance error of 0.21 mm (SD = ± 0.16) on average. This study implies that localised 3D US holds the potential for the assessment of full spinal posture by accurately and non-invasively localising vertebrae in space.

Indexed as

Spinal CurvaturesSpineHumansMagnetic Resonance ImagingPostureReproducibility of ResultsSpinal landmarksSpinal reconstructionSpine phantomUltrasoundVertebral position

Identifiers

PMID36625994
PMCPMC10030537
OpenAlexW4313908356

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read4
Read underepoch 390

Registered trials

None linked