Evidence map›Paper›PMID 36625811›Full record

ArticleJAMA2023

Association Between Regulatory Submission Characteristics and Recalls of Medical Devices Receiving 510(k) Clearance.

Alexander O Everhart, Soumya Sen, Ariel D Stern, Yi Zhu, Pinar Karaca-Mandic

Abstract read
In one paragraph

Article in JAMA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Alexander O EverhartHarvard-MIT Center for Regulatory Science, Harvard Medical School, Harvard University, Boston, Massachusetts.
Soumya SenDepartment of Information and Decision Sciences, Carlson School of Management, University of Minnesota, Minneapolis.
Ariel D SternHarvard-MIT Center for Regulatory Science, Harvard Medical School, Harvard University, Boston, Massachusetts.
Yi ZhuDepartment of Information and Decision Sciences, Carlson School of Management, University of Minnesota, Minneapolis.
Pinar Karaca-MandicDepartment of Finance, Carlson School of Management, University of Minnesota, Minneapolis.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: Most regulated medical devices enter the US market via the 510(k) regulatory submission pathway, wherein manufacturers demonstrate that applicant devices are "substantially equivalent" to 1 or more "predicate" devices (legally marketed medical devices with similar intended use). Most recalled medical devices are 510(k) devices. Objective: To examine the association between characteristics of predicate medical devices and recall probability for 510(k) devices. Design, Setting, and Participants: In this exploratory cross-sectional analysis of medical devices cleared by the US Food and Drug Administration (FDA) between 2003 and 2018 via the 510(k) regulatory submission pathway, linear probability models were used to examine associations between a 510(k) device's recall status and characteristics of its predicate medical devices. Public documents for the 510(k) medical devices were collected using FDA databases. A text extraction algorithm was applied to identify predicate medical devices cited in 510(k) regulatory submissions. Algorithm-derived metadata were combined with 2003-2020 FDA recall data. Exposures: Citation of predicate medical devices with certain characteristics in 510(k) regulatory submissions, including the total number of predicate medical devices cited by the applicant device, the age of the predicate medical devices, the lack of similarity of the predicate medical devices to the applicant device, and the recall status of the predicate medical devices. Main Outcomes and Measures: Class I or class II recall of a 510(k) medical device between its FDA regulatory clearance date and December 31, 2020. Results: The sample included 35 176 medical devices, of which 4007 (11.4%) were recalled. The applicant devices cited a mean of 2.6 predicate medical devices, with mean ages of 3.6 years and 7.4 years for the newest and oldest, respectively, predicate medical devices. Of the applicant devices, 93.9% cited predicate medical devices with no ongoing recalls, 4.3% cited predicate medical devices with 1 ongoing class I or class II recall, 1.0% cited predicate medical devices with 2 ongoing recalls, and 0.8% cited predicate medical devices with 3 or more ongoing recalls. Applicant devices citing predicate medical devices with 3 or more ongoing recalls were significantly associated with a 9.31-percentage-point increase (95% CI, 2.84-15.77 percentage points) in recall probability compared with devices without ongoing recalls of predicate medical devices, or an 81.2% increase in recall probability relative to the mean recall probability. A 1-SD increase in the total number of predicate medical devices cited by the applicant device was significantly associated with a 1.25-percentage-point increase (95% CI, 0.62-1.87 percentage points) in recall probability, or an 11.0% increase in recall probability relative to the mean recall probability. A 1-SD increase in the newest age of a predicate medical device was significantly associated with a 0.78-percentage-point decrease (95% CI, 1.29-0.30 percentage points) in recall probability, or a 6.8% decrease in recall probability relative to the mean recall probability. Conclusions and Relevance: This exploratory cross-sectional study of 510(k) medical devices cleared by the FDA between 2003 and 2018 demonstrated significant associations between 510(k) submission characteristics and recalls of medical devices. Further research is needed to understand the implications of these associations.

Indexed as

Device ApprovalMedical Device RecallsUnited States Food and Drug AdministrationAlgorithmsCross-Sectional StudiesDatabases, FactualUnited States

Identifiers

PMID36625811
PMCPMC9857565

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.