Optimizing the Patient Positioning Workflow of Patients with Pelvis, Limb, and Chest/Spine Tumors at an Ion-Beam Gantry based on Optical Surface Guidance.

Abdallah Qubala, Andrea Schwahofer, Stefan Jersemann, Saleh Eskandarian, Semi Harrabi, Patrick Naumann, Marcus Winter, Malte Ellerbrock, Jehad Shafee, Samira Abtehi and 3 more

Open access · goldAbstract read
In one paragraph

Article in Advances in radiation oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
4.0field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 16 citations in OpenAlex.

  1. Trial
  2. Multiregional assessment of surface guidance for patient positioning in radiotherapy.Technical innovations & patient support in radiation oncology · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Use of surface tracking recordings to identify pitfalls during surface-guided radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025
    Article
  7. A novel SGRT system for real-time optical surface tracking or guidance.Journal of applied clinical medical physics · 2025
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 3 institutions in 1 country.

Abdallah QubalaHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Andrea SchwahoferNational Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.
Stefan JersemannHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Saleh EskandarianHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Semi HarrabiHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Patrick NaumannHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Marcus WinterHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Malte EllerbrockHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Jehad ShafeeHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Samira AbtehiHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Klaus HerfarthHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Jürgen DebusHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Oliver JäkelHeidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany.
Heidelberger Institut für Radioonkologie · DEHeidelberg University · DEGerman Cancer Research Center · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Surface-guided radiation therapy (SGRT) has been investigated intensively to ensure correct patient positioning during a radiation therapy course. Although the implementation is well defined for photon-beam facilities, only a few analyses have been published for ion-beam therapy centers. To investigate the accuracy, reliability, and efficiency of SGRT used in ion-beam treatments against the conventional skin marks, a retrospective study of a unique SGRT installation in an ion gantry treatment room was conducted, where the environment is quite different to conventional radiation therapy. Methods and Materials: There were 32 patients, divided into 3 cohorts-pelvis, limb, and chest/spine tumors-and treated with ion-beams. Two patient positioning workflows based on 300 fractions were compared: workflow with skin marks and workflow with SGRT. Position verification was followed by planar kilo voltage imaging. After image matching, 6 degrees of freedom corrections were recorded to assess interfraction positioning errors. In addition, the time required for patient positioning, image matching, and the number of repeated kilo voltage imaging also were gathered. Results: SGRT decreased the translational magnitude shifts significantly ( Conclusions: The quality of patient positioning before ion-beam treatments has been optimized by using SGRT without additional imaging dose. SGRT clearly reduced inefficiencies in the patient positioning workflow.