Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study.

Djamel Dabli, Maeliss Loisy, Julien Frandon, Fabien de Oliveira, Azhar Mohamad Meerun, Boris Guiu, Jean-Paul Beregi, Joël Greffier

Open access · goldAbstract read
In one paragraph

Article in European radiology experimental, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Djamel DabliDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France. Djamel.dabli@chu-nimes.fr.ORCID 0000-0003-1003-1196
Maeliss LoisyDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
Julien FrandonDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
Fabien de OliveiraDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
Azhar Mohamad MeerunSaint-Eloi University Hospital, Montpellier, France.
Boris GuiuSaint-Eloi University Hospital, Montpellier, France.
Jean-Paul BeregiDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
Joël GreffierDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
Université de Montpellier · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo assess the impact of the new version of a deep learning (DL) spectral reconstruction on image quality of virtual monoenergetic images (VMIs) for contrast-enhanced abdominal computed tomography in the rapid kV-switching platform.

methodsTwo phantoms were scanned with a rapid kV-switching CT using abdomen-pelvic CT examination parameters at dose of 12.6 mGy. Images were reconstructed using two versions of DL spectral reconstruction algorithms (DLSR V1 and V2) for three reconstruction levels. The noise power spectrum (NSP) and task-based transfer function at 50% (TTF

resultsThe noise magnitude was significantly lower with DLSR V2 compared to DLSR V1 for energy levels between 40 and 60 keV by -36.5% ± 1.4% (mean ± standard deviation) for the standard level. The average NPS frequencies increased significantly with DLSR V2 by 23.7% ± 4.2% for the standard level. The highest difference in TTF

conclusionsThe DLSR V2 improves image quality and detectability of low iodine concentrations in VMIs compared to DLSR V1. This suggests a great potential of DLSR V2 to reduce iodined contrast doses.

Indexed as

Deep LearningIodineAlgorithmsImage Processing, Computer-AssistedTomography, X-Ray ComputedIodineAbdomenContrast mediaDeep learningImage processing (computer assisted)Phantoms (imaging)

Identifiers

PMID36617620
PMCPMC9826773
OpenAlexW4313814234

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.