ArticleSensors (Basel, Switzerland)2022

Repeatability of Inertial Measurement Units for Measuring Pelvic Mobility in Patients Undergoing Total Hip Arthroplasty.

Sushanth Vayalapra, Xueyang Wang, Arham Qureshi, Abhinav Vepa, Usama Rahman, Arnab Palit, Mark A Williams, Richard King, Mark T Elliott

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sushanth VayalapraDepartment of Trauma and Orthopaedics, University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK.
Xueyang WangWMG, University of Warwick, Coventry CV4 7AL, UK.
Arham QureshiDepartment of Trauma and Orthopaedics, University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK.
Abhinav VepaDepartment of Trauma and Orthopaedics, University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK.ORCID 0000-0001-5858-1109
Usama RahmanDepartment of Trauma and Orthopaedics, University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK.
Arnab PalitWMG, University of Warwick, Coventry CV4 7AL, UK.
Mark A WilliamsWMG, University of Warwick, Coventry CV4 7AL, UK.
Richard KingDepartment of Trauma and Orthopaedics, University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK.
Mark T ElliottWMG, University of Warwick, Coventry CV4 7AL, UK.ORCID 0000-0003-4000-0198

Funding

Corin (United Kingdom) NAHigh Value Manufacturing Catapult NA
6 · The paper itself

Abstract

Consideration of pelvic mobility when positioning implants for total hip arthroplasty (THA) has been shown to reduce the risk of complications such as dislocation, squeaking and excessive wear. We aim to test the repeatability of pelvic tilt measurements taken between three positions (standing, flexed-seated and step-up) by an inertial measurement unit (IMU) and hence, evaluate their reliability in screening for high pelvic mobility in patients undergoing THA. The repeated IMU measurements of pelvic tilt were analysed for consistency and compared with measures taken by x-ray analysis. Our study showed greater variation in measures taken by the IMU particularly in the flexed-seated position. The patient's pelvic tilt in this position negatively correlated with their mid-back angle, suggesting the posture of the patient is a source of variation in the flexed-seated position if not kept consistent during assessments. IMUs were overall able to produce accurate and reliable measurements of pelvic tilt; however, protocols will need to be adjusted to factor in a patient's mid-back angle when taking future readings.

Indexed as

Arthroplasty, Replacement, HipHip JointHumansPelvisPostureReproducibility of Resultsinertial measurement unitpelvic tiltreliabilitytotal hip arthroplastywearables

Identifiers

PMID36616975
PMCPMC9823306

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.