Evidence map›Paper›PMID 36616968›Full record

ArticleSensors (Basel, Switzerland)2022

A Method of Damage Detection Efficiency Enhancement of PZT Sensor Networks under Influence of Environmental and Operational Conditions.

Michal Dziendzikowski, Mateusz Heesch, Jakub Gorski, Kamil Kowalczyk, Krzysztof Dragan, Ziemowit Dworakowski

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Michal DziendzikowskiAirworthiness Division, Air Force Institute of Technology, ul. Ks. Boleslawa 6, 01-494 Warszawa, Poland.ORCID 0000-0003-2555-0052
Mateusz HeeschDepartment of Robotics and Mechatronics, Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, 30-059 Krakow, Poland.ORCID 0000-0001-9350-4125
Jakub GorskiDepartment of Robotics and Mechatronics, Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, 30-059 Krakow, Poland.ORCID 0000-0002-4574-2580
Kamil KowalczykAirworthiness Division, Air Force Institute of Technology, ul. Ks. Boleslawa 6, 01-494 Warszawa, Poland.ORCID 0000-0002-3049-7949
Krzysztof DraganAirworthiness Division, Air Force Institute of Technology, ul. Ks. Boleslawa 6, 01-494 Warszawa, Poland.ORCID 0000-0003-1857-227X
Ziemowit DworakowskiDepartment of Robotics and Mechatronics, Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, 30-059 Krakow, Poland.ORCID 0000-0002-5289-9826

Funding

National Center for Research and Development in Poland LIDER/3/0005/L-9/17/NCBR/2018
6 · The paper itself

Abstract

Two performance parameters are particularly important for the assessment of structural health monitoring (SHM) systems, i.e., their damage detection capabilities and risk of false positive indications due to varying environmental and operational conditions (EOCs). A reduced ratio of false-positive indications can be of significant importance for particular applications, for example, in aerospace, where the costs of unplanned maintenance procedures can be very high. In such cases, the reduction of the false calls ratio can be critical for the possibility of the practical application of the system, apart from damage detection efficiency and system costs. Among various sensor technologies, PZT networks are proven to be one of the most universal approaches to SHM, and they were successfully applied in different scenarios. Moreover, many EOCs which may have an impact on the risk of false positive indications have been identified. Over the years, different approaches to the influence of EOCs compensation have been proposed. Compensation methods can be tailored to the particular way in which a given measurement condition, for example, ambient temperature, alters signals acquired by the PZT network or can be formulated to be also applied in the more general case. In the paper, a method for enhancement of damage detection efficiency under influence of EOCs of general nature is proposed. The particular measurement condition affecting signals acquired by PZT sensors neither needs to be measured, which could be hard in some cases, but also nor even have to be identified. The efficiency of the proposed compensation algorithms is verified based on the example of experimental results obtained under varying temperatures.

Indexed as

AlgorithmsElectrocardiographyMonitoring, PhysiologicTemperatureZirconiumZirconiumdamage detection capabilities enhancementenvironmental and operational conditions compensationPZT transducers applicationsstructural health monitoring

Identifiers

PMID36616968
PMCPMC9823314

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.