ArticleSensors (Basel, Switzerland)2022
Comparison of Different Linewidth Measuring Methods for Narrow Linewidth Laser.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
We experimentally demonstrate a fiber laser with different linewidths based on self-injection locking (SIL) and the stimulated Brillouin scattering effect. Based on the homemade fiber laser, the error origin, resolution, and applicable range of delayed self-heterodyne interferometry (DSHI), self-correlation envelope linewidth detection (SCELD) and Voigt fitting are investigated numerically and experimentally. The selection of the linewidth measuring method should meet the following conclusions: an approximately Lorentzian self-heterodyne spectrum without the pedestal and high-intensity sinusoidal jitter is a prerequisite for DSHI; the SCELD needs a suitable length of delay fiber for eliminating flicker noise and dark noise of the electrical spectrum analyzer; a non-Lorentzian self-heterodyne spectrum without a pedestal is an indispensable element for Voigt fitting. According to the experimental results, the laser Lorentzian linewidth of SIL changes from 1.7 kHz to 587 Hz under different injection powers. When the Brillouin erbium fiber laser is utilized, the Lorentzian linewidth is measured to be 60 ± 5 Hz.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.