Evidence map›Paper›PMID 36616646›Full record

ArticleSensors (Basel, Switzerland)2022

A Flexible Pressure Sensor with a Mesh Structure Formed by Lost Hair for Human Epidermal Pulse Wave Monitoring.

Xue Wang, Zhiping Feng, Peng Li, Luna Wang, Liang Chen, Yufen Wu, Jin Yang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xue WangDepartment of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems Ministry of Education, Chongqing University, Chongqing 400044, China.
Zhiping FengDepartment of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems Ministry of Education, Chongqing University, Chongqing 400044, China.
Peng LiDepartment of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems Ministry of Education, Chongqing University, Chongqing 400044, China.
Luna WangDepartment of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems Ministry of Education, Chongqing University, Chongqing 400044, China.
Liang ChenDepartment of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems Ministry of Education, Chongqing University, Chongqing 400044, China.
Yufen WuCollege of Physics and Electronic Engineering, Chongqing Normal University, Chongqing 401331, China.
Jin YangDepartment of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems Ministry of Education, Chongqing University, Chongqing 400044, China.

Funding

the Fundamental Research Funds for the Central Universities 2018CDQYGD0020the Fundamental Research Funds for the Central Universities cqu2018CDHB1A05the National Key Research and Development Project 2021YFA1201602the Natural Science Foundation of Innovative Research Groups cstc2020jcyj-cxttX0005the Natural Science Foundation Projects of Chongqing cstc2022ycjh-bgzxm0206
6 · The paper itself

Abstract

Flexible pressure sensors with the capability of monitoring human vital signs show broad application prospects in personalized healthcare. In this work, a hair-based flexible pressure sensor (HBPS) consisting of lost hair and polymer films was proposed for the continuous monitoring of the human epidermal arterial pulse waveform. A macroscale mesh structure formed by lost hair provides a simplified spacer that endows the triboelectric-based flexible pressure sensor with sufficient contact-separation space. Based on this mesh structure design, the hair-based flexible pressure sensor can respond to the slight pressure change caused by an object with 5 mg weight and hold a stable output voltage under 1-30 Hz external pressure excitation. Additionally, the hair-based flexible pressure sensor showed great sensitivity (0.9 V/kPa) and decent stability after 4500 cycles of operation. Given these compelling features, the HBPS can successfully measure the human epidermal arterial pulses with obvious details at different arteries. The proposed HBPS can also be used to monitor the pulse signals of different subjects. Furthermore, the three different pulse wave transmission time (PTT) values (PTT-foot, PTT-middle, and PTT-peak) can be obtained by simultaneously monitoring human pulse and electrocardiogram signals, which has enormous application potential for assessing cardiovascular system health.

Indexed as

PulseSurgical MeshArteriesHairHeart RateHumansflexible pressure sensorhuman epidermal pulse wavelost hairpulse wave transmission time

Identifiers

PMID36616646
PMCPMC9823516

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked