ArticleJournal of clinical medicine2023
Interventional Occlusion of Large Patent Ductus Arteriosus in Adults with Severe Pulmonary Hypertension.
Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 7 citations in OpenAlex.
- Off-Label 16-mm VSD Occluder for Closure of a Giant PDA With Severe Pulmonary Hypertension.JACC. Case reports · 2026Article
- Transcatheter Closure of Patent Ductus Arteriosus in Adults.Current cardiology reports · 2026Review
- Transient early increase in echocardiographically estimated pulmonary artery pressure after closure of a large patent ductus arteriosus in an adult: a case report.Frontiers in medicine · 2026Article
- Common shunt lesions with pulmonary hypertension-who will benefit from surgery?Indian journal of thoracic and cardiovascular surgery · 2025Review
- Case Report: Non-reactive vasoreactivity testing in a patient with patent ductus arteriosus with pulmonary hypertension: is there still a way to turn things around?Frontiers in cardiovascular medicine · 2025Article
- [Interventional treatment in an adult: postductal aortic coarctation, aortic stenosis and persistence of the ductus arteriosum].Archivos de cardiologia de Mexico · 2024Article
- Identification and Functional Verification of CITED2 Gene Promoter Region in Patients with Patent Ductus Arteriosus.International journal of molecular sciences · 2023Article
- Procedural outcome and safety of percutaneous patent ductus arteriosus occlusion in adults.Annals of pediatric cardiologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 1 institution in 1 country.
Funding
Abstract
(1) Background: the indications for transcatheter closure of large patent ductus arteriosus (PDA) with severe pulmonary hypertension (PH) are still unclear, and scholars have not fully elucidated the factors that affect PH prognosis. (2) Methods: we retrospectively enrolled 134 consecutive patients with a PDA diameter ≥10 mm or a ratio of PDA and aortic >0.5. We collected clinical data to explore the factors affecting follow-up PH. (3) Results: 134 patients (mean age 35.04 ± 10.23 years; 98 women) successfully underwent a transcatheter closure, and all patients had a mean pulmonary artery pressure (mPAP) >50 mmHg. Five procedures were deemed to have failed because their mPAP did not decrease, and the patients experienced uncomfortable symptoms after the trial occlusion. The average occluder (pulmonary end) size was almost twice the PDA diameter (22.33 ± 4.81 mm vs. 11.69 ± 2.18 mm). Left ventricular end-diastolic dimension (LVEDD), mPAP, and left ventricular ejection fraction (LVEF) significantly reduced after the occlusion, and LVEF recovered during the follow-up period. In total, 42 of the 78 patients with total pulmonary resistance >4 Wood Units experienced clinical outcomes, and all of them had PH in the follow-up, while 10 of them had heart failure, and 4 were hospitalized again because of PH. The results of a logistic regression analysis revealed that the postoperative mPAP had an independent risk factor (odds ratio = 1.069, 95% confidence interval: 1.003 to 1.140, p = 0.040) with a receiver operating characteristic curve cut-off value of 35.5 mmHg (p < 0.001). (4) Conclusions: performing a transcatheter closure of large patent ductus arteriosus is feasible, and postoperative mPAP was a risk factor that affected the follow-up PH. Patients with a postoperative mPAP >35.5 mmHg should be considered for targeted medical therapy or should undergo right heart catheterization again after the occlusion.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.