Evidence map›Paper›PMID 36614950›Full record

ArticleJournal of clinical medicine2022

Laser Efficiency and Laser Safety: Holmium YAG vs. Thulium Fiber Laser.

Alba Sierra, Mariela Corrales, Bhaskar Somani, Olivier Traxer

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
5.2field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 36 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. SemirigidMaedica · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 3 countries.

Alba SierraUrology Department, Hospital Clínic de Barcelona, Villarroel 170, 08036 Barcelona, Spain.
Mariela CorralesGRC Urolithiasis No. 20, Tenon Hospital, Sorbonne University, F-75020 Paris, France.ORCID 0000-0002-1461-8464
Bhaskar SomaniUrology Department, University Hospital Southampton NHS Trust, Southampton SO16 6YD, UK.ORCID 0000-0002-6248-6478
Olivier TraxerGRC Urolithiasis No. 20, Tenon Hospital, Sorbonne University, F-75020 Paris, France.
Sorbonne Université · FRUniversity Hospital Southampton NHS Foundation Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Objective: To support the efficacy and safety of a range of thulium fiber laser (TFL) pre-set parameters for laser lithotripsy: the efficiency is compared against the Holmium:YAG (Ho:YAG) laser in the hands of juniors and experienced urologists using an in vitro ureteral model; the ureteral damage of both lasers is evaluated in an in vivo porcine model. (2) Materials and Methods: Ho:YAG laser technology and TFL technology, with a 200 µm core-diameter laser fibers in an in vitro saline ureteral model were used. Each participant performed 12 laser sessions. Each session included a 3-min lasering of stone phantoms (Begostone) with each laser technology in six different pre-settings retained from the Coloplast TFL Drive user interface pre-settings, for stone dusting: 0.5 J/10 Hz, 0.5 J/20 Hz, 0.7 J/10 Hz, 0.7 J/20 Hz, 1 J/12 Hz and 1 J/20 Hz. Both lasers were also used in three in vivo porcine models, lasering up to 20 W and 12 W in the renal pelvis and the ureter, respectively. Temperature was continuously recorded. After 3 weeks, a second look was done to verify the integrity of the ureters and kidney and an anatomopathological analysis was performed. (3) Results: Regarding laser lithotripsy efficiency, after 3 min of continuous lasering, the overall ablation rate (AR) percentage was 27% greater with the TFL technology (p < 0.0001). The energy per ablated mass [J/mg] was 24% lower when using the TFL (p < 0.0001). While junior urologists performed worse than seniors in all tests, they performed better when using the TFL than Ho:YAG technology (36% more AR and 36% fewer J/mg). In the in vivo porcine model, no urothelial damage was observed for both laser technologies, neither endoscopically during lasering, three weeks later, nor in the pathological test. (4) Conclusions: By using Coloplast TFL Drive GUI pre-set, TFL lithotripsy efficiency is higher than Ho:YAG laser, even in unexperienced hands. Concerning urothelial damage, both laser technologies with low power present no lesions.

Indexed as

holmium YAGkidney calculilaser efficiencylaser safetylaser settingslaser usabilitylithotripsythulium fiber laserureteroscopy

Identifiers

PMID36614950
PMCPMC9821183
OpenAlexW4313328580

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.