Evidence map›Paper›PMID 36605476›Full record

ArticleEuropean journal of breast health2023

A Dosimetric Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy in Patients Treated with Post-Mastectomy Radiotherapy.

Samuel Adeneye, Michael Akpochafor, Nusirat Adedewe, Muhammad Habeebu, Ramotallah Jubril, Abe Adebayo, Omolola Salako, Adedayo Joseph, Inioluwa Ariyo, Eseoghene Awhariado and 1 more

Open access · diamondAbstract read
In one paragraph

Article in European journal of breast health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Samuel AdeneyeNSIA-LUTH Cancer Center, Lagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0003-3239-2785
Michael AkpochaforLagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0001-5903-676X
Nusirat AdedeweNSIA-LUTH Cancer Center, Lagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0002-8677-8192
Muhammad HabeebuNSIA-LUTH Cancer Center, Lagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0002-1466-3070
Ramotallah JubrilLagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0002-2115-5162
Abe AdebayoNSIA-LUTH Cancer Center, Lagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0003-1604-6815
Omolola SalakoLagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0003-3165-8879
Adedayo JosephNSIA-LUTH Cancer Center, Lagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0002-7938-1218
Inioluwa AriyoNSIA-LUTH Cancer Center, Lagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0001-9772-0159
Eseoghene AwhariadoNSIA-LUTH Cancer Center, Lagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0001-9023-1088
Rasak LawalNSIA-LUTH Cancer Center, Lagos University Teaching Hospital, Idi-araba, Lagos, Nigeria.ORCID https://orcid.org/0000-0003-3272-257X
Lagos University Teaching Hospital · NG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Radiotherapy continues to play an important role in the management of breast cancer. This study compared the dosimetric differences between the techniques of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in breast cancer patients who had radiotherapy after mastectomy. Materials and Methods: Forty post-mastectomy patients (19 right-sided breast and 21 left-sided breast) treated with the IMRT technique using 7-9 fields who were re-planned with VMAT using 2 coplanar arc on the Varian Vital beam linear accelerator between January, 2020 and August, 2021 were included in this study. The patients received 42 Gy in 15 fractions to the chest wall, lymph nodes and supraclavicular nodes. The dosimetric parameter for planning target volume (PTV), organs at risk (OAR) and the integral dose to the body were analysed. Student's t-test for two independent means was used to analyse the dosimetric differences between the plans. Results: Clinical goals were achieved for both techniques. In terms of PTV coverage at 95% (IMRT: 712.17±233) vs (VMAT: 694.9±214) and the homogeneity index (IMRT: 0.075±0.04) vs (VMAT: 0.104±0.03), IMRT resulted in better dose coverage and homogeneity than VMAT. However, with the conformity index, no significant difference was seen. As regards the OARs, the mean doses, V Conclusion: With IMRT, better PTV coverage, homogeneity and OAR sparing were observed. Additionally, VMAT resulted in a lower delivery time than IMRT. Overall, both techniques offered dosimetric qualities that were clinically acceptable.

Indexed as

Cancerconformityhomogeneitymastectomyradiotherapy

Identifiers

PMID36605476
PMCPMC9806941
OpenAlexW4313258819

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked