Motion artifact reduction for magnetic resonance imaging with deep learning and k-space analysis.

Long Cui, Yang Song, Yida Wang, Rui Wang, Dongmei Wu, Haibin Xie, Jianqi Li, Guang Yang

Abstract read
PubMed Publisher
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Long CuiDepartment of Physics, Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
Yang SongDepartment of Physics, Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
Yida WangDepartment of Physics, Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
Rui WangDepartment of Physics, Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
Dongmei WuDepartment of Physics, Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
Haibin XieDepartment of Physics, Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
Jianqi LiDepartment of Physics, Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
Guang YangDepartment of Physics, Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.ORCID 0000-0001-8942-427X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Motion artifacts deteriorate the quality of magnetic resonance (MR) images. This study proposes a new method to detect phase-encoding (PE) lines corrupted by motion and remove motion artifacts in MR images. 67 cases containing 8710 slices of axial T2-weighted images from the IXI public dataset were split into three datasets, i.e., training (50 cases/6500 slices), validation (5/650), and test (12/1560) sets. First, motion-corrupted k-spaces and images were simulated using a pseudo-random sampling order and random motion tracks. A convolutional neural network (CNN) model was trained to filter the motion-corrupted images. Then, the k-space of the filtered image was compared with the motion-corrupted k-space line-by-line, to detect the PE lines affected by motion. Finally, the unaffected PE lines were used to reconstruct the final image using compressed sensing (CS). For the simulated images with 35%, 40%, 45%, and 50% unaffected PE lines, the mean peak signal-to-noise ratio (PSNRs) of resulting images (mean±standard deviation) were 36.129±3.678, 38.646±3.526, 40.426±3.223, and 41.510±3.167, respectively, and the mean structural similarity (SSIMs) were 0.950±0.046, 0.964±0.035, 0.975±0.025, and 0.979±0.023, respectively. For images with more than 35% PE lines unaffected by motion, images reconstructed with proposed algorithm exhibited better quality than those images reconstructed with CS using 35% under-sampled data (PSNR 37.678±3.261, SSIM 0.964±0.028). It was proved that deep learning and k-space analysis can detect the k-space PE lines affected by motion and CS can be used to reconstruct images from unaffected data, effectively alleviating the motion artifacts.

Indexed as

Deep LearningArtifactsImage Processing, Computer-AssistedMagnetic Resonance ImagingMotionNeural Networks, Computer

Identifiers

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.