Evidence map›Paper›PMID 36601367›Full record

ArticleJAMIA open2022

Designing and implementing smart glass technology for emergency medical services: a sociotechnical perspective.

Zhan Zhang, Noubrab Ashika Ramiya Ramesh Babu, Kathleen Adelgais, Mustafa Ozkaynak

Erratum issuedAbstract read
In one paragraph

Article in JAMIA open, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Zhan ZhangDepartment of Information Technology, School of Computer Science and Information Systems, Pace University, New York, New York, USA.
Noubrab Ashika Ramiya Ramesh BabuDepartment of Information Technology, School of Computer Science and Information Systems, Pace University, New York, New York, USA.
Kathleen AdelgaisSchool of Medicine, University of Colorado, Aurora, Colorado, USA.
Mustafa OzkaynakCollege of Nursing, University of Colorado, Aurora, Colorado, USA.ORCID https://orcid.org/0000-0002-5085-5125

Funding

AHRQ HHS R21 HS028104
6 · The paper itself

Abstract

Objective: This study aims to investigate key considerations and critical factors that influence the implementation and adoption of smart glasses in fast-paced medical settings such as emergency medical services (EMS). Materials and Methods: We employed a sociotechnical theoretical framework and conducted a set of participatory design workshops with 15 EMS providers to elicit their opinions and concerns about using smart glasses in real practice. Results: Smart glasses were recognized as a useful tool to improve EMS workflow given their hands-free nature and capability of processing and capturing various patient data. Out of the 8 dimensions of the sociotechnical model, we found that hardware and software, human-computer interface, workflow, and external rules and regulations were cited as the major factors that could influence the adoption of this novel technology. EMS participants highlighted several key requirements for the successful implementation of smart glasses in the EMS context, such as durable devices, easy-to-use and minimal interface design, seamless integration with existing systems and workflow, and secure data management. Discussion: Applications of the sociotechnical model allowed us to identify a range of factors, including not only technical aspects, but also social, organizational, and human factors, that impact the implementation and uptake of smart glasses in EMS. Our work informs design implications for smart glass applications to fulfill EMS providers' needs. Conclusion: The successful implementation of smart glasses in EMS and other dynamic healthcare settings needs careful consideration of sociotechnical issues and close collaboration between different stakeholders.

Indexed as

emergency medical servicessmart glassessociotechnicalworkflow

Identifiers

PMID36601367
PMCPMC9801961

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.