Evidence map›Paper›PMID 36598604›Full record

ArticleArchives of orthopaedic and trauma surgery2023

Preventing varus collapse in proximal humerus fracture fixation: 90-90 dual plating versus endosteal fibular allograft strut.

Ravi Patel, Justin R Brown, Jon W Miles, Grant J Dornan, Christopher Bartolomei, Rony-Orijit Dey Hazra, Leslie B Vidal, Peter J Millett

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Ravi PatelSteadman Philippon Research Institute, 181 W. Meadow Dr. Ste 1000, Vail, CO, 81657, USA.
Justin R BrownSteadman Philippon Research Institute, 181 W. Meadow Dr. Ste 1000, Vail, CO, 81657, USA.
Jon W MilesSteadman Philippon Research Institute, 181 W. Meadow Dr. Ste 1000, Vail, CO, 81657, USA.
Grant J DornanSteadman Philippon Research Institute, 181 W. Meadow Dr. Ste 1000, Vail, CO, 81657, USA.
Christopher BartolomeiSteadman Philippon Research Institute, 181 W. Meadow Dr. Ste 1000, Vail, CO, 81657, USA.
Rony-Orijit Dey HazraSteadman Philippon Research Institute, 181 W. Meadow Dr. Ste 1000, Vail, CO, 81657, USA.
Leslie B VidalSteadman Philippon Research Institute, 181 W. Meadow Dr. Ste 1000, Vail, CO, 81657, USA.
Peter J MillettSteadman Philippon Research Institute, 181 W. Meadow Dr. Ste 1000, Vail, CO, 81657, USA. drmillett@thesteadmanclinic.com.ORCID http://orcid.org/0000-0002-8298-3746
Steadman Philippon Research Institute · US

Funding

DePuy Synthes Materials
6 · The paper itself

Abstract

introductionScrew cut out and varus collapse are the most common complication of locked plate fixation of proximal humerus fractures. The purpose of this study was to compare dual plating and endosteal fibular allograft struts as augmentation strategies to prevent varus collapse. MATERIALS AND

methodsA trapezoidal osteotomy was created at the metaphysis to create a 2-part proximal humerus model in 18 paired shoulder specimens. Each specimen was assigned to group A, B, or C and was fixed with either a lateral locking plate, a lateral locking plate and anterior one-third tubular plate in an orthogonal 90/90 configuration, or a lateral locking plate with intramedullary fibular strut, respectively. The specimens were stressed in axial compression to failure. Displacement, elastic limit, ultimate load, and stiffness were recorded and calculated.

resultsThere was no difference in mean cyclic displacement between the three groups (0.71 mm vs 0.89 mm vs 0.61 mm for Group A, B, C, respectively). Lateral plating demonstrated the greatest absolute and relative displacement at the elastic limit (5.3 mm ± 1.5 and 4.4 mm ± 1.3) without significance. The elastic limit or yield point was greatest for fibular allograft, Group C (1223 N ± 501 vs 1048 N ± 367 for Group B and 951 N ± 249 for Group A) without significance.

conclusionsDual plating of proximal humerus fractures in a 90-90 configuration demonstrates similar biomechanical properties as endosteal fibular strut allograft. Both strategies demonstrate superior stiffness to isolated lateral locked plating.

Indexed as

Humeral FracturesShoulder FracturesAllograftsBiomechanical PhenomenaBone PlatesFracture Fixation, InternalHumansHumerus90–90 configurationDual platingFibular allograftHumerus fixationHumerus fractureProximal humerus fracture

Identifiers

PMID36598604
OpenAlexW4313488388

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.