ArticleArthroplasty (London, England)2023
Biomechanical analysis of different levels of constraint in TKA during daily activities.
Article in Arthroplasty (London, England), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 21 citations in OpenAlex.
- Pooled it
- Knee medial tightness after total knee arthroplasty is associated with superior clinical outcomes in Chinese patients: a retrospective cohort study.Journal of orthopaedic surgery and research · 2026Article
- Biomechanical analysis of surgical alignment and design in total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2026Article
- Limb salvage in multiple revision total knee arthroplasty using customised implants: When sleeves and cones are no longer an option.Journal of experimental orthopaedics · 2026Article
- Increased varus deformity requires greater personalisation of alignment: A finite element biomechanical study.Journal of experimental orthopaedics · 2025Article
- Mobile-bearing versus Medial-pivot Designs in Total Knee Arthroplasty: A Meta-analysis.Knee surgery & related research · 2025Review
- In Vitro Verification of Simulated Daily Activities Using Implant-Specific Kinematics from In Vivo Measurements.Bioengineering (Basel, Switzerland) · 2024Article
- Effect of design and surgical parameters variations in mobile-bearing versus fixed-bearing unicompartmental knee arthroplasty: A finite element analysis.Journal of experimental orthopaedics · 2024Article
- Article
- Biomechanical analysis of patient specific cone vs conventional stem in revision total knee arthroplasty.Journal of orthopaedic surgery and research · 2024Article
- Computational Lower Limb Simulator Boundary Conditions to Reproduce Measured TKA Loading in a Cohort of Telemetric Implant Patients.Bioengineering (Basel, Switzerland) · 2024Article
- Article
- Application strategy of finite element analysis in artificial knee arthroplasty.Frontiers in bioengineering and biotechnology · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundNumerous total knee prosthetic implants are currently available on the orthopedic market, and this variety covers a set of different levels of constraint: among the various models available, a significant role is covered by mobile bearing cruciate-retaining design with an ultra-congruent insert, mobile bearing cruciate-retaining design, fixed-bearing posterior stabilized prosthesis and fixed-bearing constrained condylar knee. A biomechanical comparative study among them could therefore be helpful for the clinical decision-making process. This study aimed to compare the effect of these different levels of constraint in the knee biomechanics of a patient, in three different configurations representing the typical boundary conditions experienced by the knee joint during daily activities.
methodThe investigation was performed via finite element analysis with a knee model based on an already published and validated one. Four different types of prosthesis designs were analyzed: two mobile-bearing models and two fixed-bearing models, each one having a different level of constraint. The different designs were incorporated in to the 3D finite element model of the lower leg and analyzed in three different configurations reproducing the landing and the taking-off phases occurring during the gait cycle and chair-rising. Implant kinetics (in terms of polyethylene contact areas and contact pressure), polyethylene and tibial bone stresses were calculated under three different loading conditions for each design.
resultsThe tibial stress distribution in the different regions of interest of the tibia remains relatively homogeneous regardless of the type of design used. The main relevant difference was observed between the mobile and fixed-bearing models, as the contact areas were significantly different between these models in the different loading conditions. As a consequence, significant changes in the stress distribution were observed at the interface between the prosthetic components, but no significant changes were noted on the tibial bone. Moreover, the different models exhibited a symmetrical medial and lateral distribution of the contact areas, which was not always common among all the currently available prostheses (i.e. medial pivot designs).
conclusionThe changes of the prosthetic implant did not induce a big variation of the stress distribution in the different regions of the tibial bone, while they significantly changed the distribution of stress at the interface between the prosthetic components.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.