ArticleLangenbeck's archives of surgery2023
Hybrid esophagogastric tube anastomosis after minimally invasive McKeown esophagectomy to prevent stenosis in patients with esophageal cancer.
Article in Langenbeck's archives of surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
Corrections and comments
- Erratum issued
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe use of a small circular stapler has been reported to increase the incidence of benign anastomotic stenosis in reconstruction. In circular stapling anastomosis after esophagectomy, the anastomotic lumen is dependent on the size of the esophagus and the replacement organ. We developed a new and foolproof method to prevent stenosis in esophagogastric tube anastomosis for patients with esophageal cancer that is not dependent on operator skill.
methodsSeven patients with esophageal squamous cell carcinoma underwent minimally invasive McKeown esophagectomy in our hospital. Esophagogastric tube anastomosis was tried for all patients using the novel "hybrid esophagogastric tube anastomosis" technique. A 21-mm circular stapler was applied to perform an end-to-side anastomosis between the cervical esophagus and the posterior wall of the gastric tube. Then, a 30-mm linear stapler was positioned in the esophagogastric anastomosis formed by the 21-mm circular stapler with the anvil fork inserted into the esophagus and the cartridge fork inserted into the gastric tube. A supplementary side-to-side anastomosis of appropriately 15 mm was created. Afterward, the entry hole was closed with a linear stapler.
resultsThe hybrid esophagogastric tube anastomosis was successful in all seven patients receiving it between June 2020 and March 2022. No postoperative complications related to this anastomosis were observed in any of the patients. Five patients underwent follow-up gastrointestinal endoscopy at 6 months after esophagectomy. No patient had an anastomotic stenosis.
conclusionsHybrid esophagogastric tube anastomosis can be performed easily and safely and can reduce the complications associated with anastomosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.