Evidence map›Paper›PMID 36594436›Full record

ArticleMagnetic resonance in medicine2023

Single-spoke binning: Reducing motion artifacts in abdominal radial stack-of-stars imaging.

Ivo T Maatman, Sjoerd Ypma, Marc Kachelrieß, Yannick Berker, Erik van der Bijl, Kai Tobias Block, John J Hermans, Marnix C Maas, Tom W J Scheenen

Open access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Free-breathing MRI techniques for fat and RMagma (New York, N.Y.) · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 3 countries.

Ivo T MaatmanDepartment of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.ORCID 0000-0002-9697-2351
Sjoerd YpmaDepartment of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
Marc KachelrießDivision of X-Ray Imaging and Computed Tomography, German Cancer Research Center (DKFZ), Heidelberg, Germany.
Yannick BerkerHopp Children's Cancer Center Heidelberg (KiTZ), Heidelberg, Germany.ORCID 0000-0002-6707-0834
Erik van der BijlDepartment of Radiation Oncology, Radboud University Medical Center, Nijmegen, The Netherlands.
Kai Tobias BlockDepartment of Radiology, NYU Langone Health, New York, New York, USA.
John J HermansDepartment of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
Marnix C MaasDepartment of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
Tom W J ScheenenDepartment of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
Radboud University Nijmegen · NLGerman Cancer Research Center · DENYU Langone Health · US

Funding

TR&D 4: Revealing Microstructure: Biophysical modeling and validation for discovery and clinical careP41EB017183 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI Christopher M Collins · 2014 to 2026
$19.3M
NIBIB NIH HHS P41 EB017183
6 · The paper itself

Abstract

purposeTo increase the effectiveness of respiratory gating in radial stack-of-stars MRI, particularly when imaging at high spatial resolutions or with multiple echoes.

methodsFree induction decay (FID) navigators were integrated into a three-dimensional gradient echo radial stack-of-stars pulse sequence. These navigators provided a motion signal with a high temporal resolution, which allowed single-spoke binning (SSB): each spoke at each phase encode step was sorted individually to the corresponding motion state of the respiratory signal. SSB was compared with spoke-angle binning (SAB), in which all phase encode steps of one projection angle were sorted without the use of additional navigator data. To illustrate the benefit of SSB over SAB, images of a motion phantom and of six free-breathing volunteers were reconstructed after motion-gating using either method. Image sharpness was quantitatively compared using image gradient entropies.

resultsThe proposed method resulted in sharper images of the motion phantom and free-breathing volunteers. Differences in gradient entropy were statistically significant (p = 0.03) in favor of SSB. The increased accuracy of motion-gating led to a decrease of streaking artifacts in motion-gated four-dimensional reconstructions. To consistently estimate respiratory signals from the FID-navigator data, specific types of gradient spoiler waveforms were required.

conclusionSSB allowed high-resolution motion-corrected MR imaging, even when acquiring multiple gradient echo signals or large acquisition matrices, without sacrificing accuracy of motion-gating. SSB thus relieves restrictions on the choice of pulse sequence parameters, enabling the use of motion-gated radial stack-of-stars MRI in a broader domain of clinical applications.

Indexed as

ArtifactsImage Interpretation, Computer-AssistedAbdomenHumansImaging, Three-DimensionalMagnetic Resonance ImagingMotionRespirationFID navigatorsmotion binningmotion correctionradial samplingrespiratory gating

Identifiers

PMID36594436
PMCPMC11955222
OpenAlexW4313454060

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.