ArticleJournal of the West African College of Surgeons
Bland-Altman Plot: Agreement Between Ultrasound-measured Placenta Thickness and Other Biometric Parameters in the Determination of Gestational Age.
Article in Journal of the West African College of Surgeons. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The aim of this article is to evaluate the agreement of placenta thickness (PT) with other foetal biometric parameters in the determination of gestational age (GA) in normal singleton foetuses. Materials and Methods: The study was a cross-sectional descriptive study conducted among 406 consecutively recruited pregnant women with singleton foetuses at 15-40 weeks of gestation at the National Hospital, Abuja, Nigeria from October to December 2019. Biparietal diameter (BPD), femur length (FL), head circumference (HC), abdominal circumference (AC), and PT were measured using standard measurement protocols. Bland and Altman (BA) plots were used to compare PT and other foetal biometric parameters. The significant statistical level was determined at a critical value of Results: The mean age of study participants was 31.8 ± 4.8 years. The BA plot of PT and HC demonstrated a normal distribution; the mean difference was around zero (3.968) and 95% of the measurements fell within 2SD of the mean. The BA plot of HC and AC measurements also showed that the 95% limits of agreement for differences fell within 10% of the mean of the measurements (-4.236 to 15.987 with a mean difference of 5.876), indicating good agreement between the two pairs of variables. However, BA plots between PT and BPD as well as PT and FL showed no agreement. Conclusion: This study indicates that there is good agreement or comparability between PT and HC measurements as well as between PT and AC measurements. Hence, either HC or AC measurements may be interchangeable with PT measurements in the ultrasound determination of GA. However, PT measurements did not agree well with BPD and FL measurements, respectively.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.