Evidence map›Paper›PMID 36590245›Full record

ArticleHardwareX2023

BIMMS: A versatile and portable system for biological tissue and electrode-tissue interface electrical characterization.

Louis Regnacq, Yannick Bornat, Olivier Romain, Florian Kolbl

Abstract read
In one paragraph

Article in HardwareX, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Louis RegnacqETIS CNRS UMR 8051, CY Cergy Paris University, ENSEA, France.
Yannick BornatUniv. Bordeaux, Bordeaux INP, IMS CNRS UMR 5218, Aquitaine, Talence, France.
Olivier RomainETIS CNRS UMR 8051, CY Cergy Paris University, ENSEA, France.
Florian KolblETIS CNRS UMR 8051, CY Cergy Paris University, ENSEA, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The presented design is a low-cost, compact, and open-source USB-controlled platform for biological tissue and electrode-tissue interface electrical measurements, capable of potentiostatic and galvanostatic electrical impedance spectroscopy up to 10 MHz and cyclic voltammetry with voltage compliance of +-8 V and up to 2.4 mA while ensuring tissue-safety conditions. The data acquisition and generation are based on an Analog Discovery 2 platform (Digilent, USA). We provide accuracy analysis and comparisons with a commercially available calibrated impedance analyzer. Impedance measurements are demonstrated on implanted electrodes for neural stimulation and on an isolated ex-vivo calf brain as an example use case of the presented design.

Indexed as

Cyclic voltammetryElectrode-tissue interfaceImpedance spectroscopyImplantable electrodesMultisinePotentiostat