Evidence map›Paper›PMID 36589595›Full record

ArticleBiomedical optics express2022

Motion-tracking Brillouin microscopy for in-vivo corneal biomechanics mapping.

Hongyuan Zhang, Lara Asroui, J Bradley Randleman, Giuliano Scarcelli

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
4.2field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 33 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Brillouin microscopy.Nature reviews. Methods primers · 2024
    Article
  15. Article
  16. Review
  17. Computational and structural biotechnology journal · 2023
    Review
  18. Article
  19. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Hongyuan ZhangCole Eye Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH 44195, USA.ORCID https://orcid.org/0000-0002-4949-6882
Lara AsrouiCole Eye Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH 44195, USA.
J Bradley RandlemanCole Eye Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH 44195, USA.
Giuliano ScarcelliFischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742, USA.ORCID https://orcid.org/0000-0002-1736-077X
Cleveland Clinic · USUniversity of Maryland, College Park · US

Funding

RESOURCE/SERVICE CORE C - MOLECULAR INFORMATICS MODULEP30EY025585 · NEI · CLEVELAND CLINIC LERNER COM-CWRU · PI Brian D Perkins · 2016 to 2026
$7.7M
Cornea biomechanical analysis with Brillouin microscopyR01EY028666 · NEI · UNIV OF MARYLAND, COLLEGE PARK · PI James Bradley Randleman, Giuliano Scarcelli · 2018 to 2026
$4.1M
NEI NIH HHS P30 EY025585NEI NIH HHS R01 EY028666
6 · The paper itself

Abstract

Corneal biomechanics play a critical role in maintaining corneal shape and thereby directly influence visual acuity. However, direct corneal biomechanical measurement in-vivo with sufficient accuracy and a high spatial resolution remains an open need. Here, we developed a three-dimensional (3D) motion-tracking Brillouin microscope for in-vivo corneal biomechanics mapping. The axial tracking utilized optical coherence tomography, which provided a tracking accuracy better than 3 µm. Meanwhile, 10 µm lateral tracking was achieved by tracking pupils with digital image processing. The 3D tracking enabled reconstruction of depth-dependent Brillouin distribution with a high spatial resolution. This superior technical performance enabled the capture of high-quality mechanical mapping in vivo even while the subject was breathing normally. Importantly, we improved Brillouin spectral measurements to achieve relative accuracy better than 0.07% verified by rubidium absorption frequencies, with 0.12% stability over 2000 seconds. These specifications finally yield the Brillouin measurement sensitivity that is required to detect ophthalmology-relevant corneal biomechanical properties.

Identifiers

PMID36589595
PMCPMC9774862
OpenAlexW4304893085

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.