Evidence map›Paper›PMID 36589023›Full record

ArticleBasic and clinical neuroscience

A New and Simple Method for Spinal Cord Injury Induction in Mice.

Zahra Zeraatpisheh, Esmaeil Mirzaei, Mohammad Nami, Hamed Alipour, Somayeh Ghasemian, Hassan Azari, Hadi Aligholi

Open access · diamondAbstract read
In one paragraph

Article in Basic and clinical neuroscience. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Zahra ZeraatpishehDepartment of Neuroscience, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran.ORCID https://orcid.org/0000-0002-6153-3551
Esmaeil MirzaeiDepartment of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran.ORCID https://orcid.org/0000-0002-0176-5123
Mohammad NamiDepartment of Neuroscience, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran.ORCID https://orcid.org/0000-0003-1410-5340
Hamed AlipourDepartment of Tissue Engineering & Applied cell Sciences, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran.ORCID https://orcid.org/0000-0002-1300-8111
Somayeh GhasemianGenetic Laboratory, Shiraz Fertility Center, Shiraz, Iran.
Hassan AzariDepartment of Neurosurgery, McKnight Brain Institute, University of Florida, Gainesville, Florida 32611, USA.ORCID https://orcid.org/0000-0002-8021-3166
Hadi AligholiDepartment of Neuroscience, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran.ORCID https://orcid.org/0000-0002-2241-5296
Shiraz University of Medical Sciences · IRShiraz University · IRUniversity of Florida · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Spinal Cord Injury (SCI) is a devastating disease with poor clinical outcomes. Animal models provide great opportunities to expand our horizons in identifying SCI pathophysiological mechanisms and introducing effective treatment strategies. The present study introduces a new murine contusion model. Methods: A simple, cheap, and reproducible novel instrument was designed, which consisted of a body part, an immobilization piece, and a bar-shaped weight. The injury was inflicted to the spinal cord using an 8-g weight for 5, 10, or 15 minutes after laminectomy at the T9 level in male C57BL/6 mice. Motor function, cavity formation, cell injury, and macrophage infiltration were evaluated 28 days after injury. Results: The newly designed instrument minimized adverse spinal movement during injury induction. Moreover, no additional devices, such as a stereotaxic apparatus, were required to stabilize the animals during the surgical procedure. Locomotor activity was deteriorated after injury. Furthermore, tissue damage and cell injury were exacerbated by increasing the duration of weight exertion. In addition, macrophage infiltration around the injured tissue was observed 28 days after injury. Conclusion: This novel apparatus could induce a controllable SCI with a clear cavity formation in mice. No accessory elements are needed, which can be used in future SCI studies. Highlights: A simple and precise method has been introduced for creating Spinal Cord Injury (SCI) in mice by a novel device.The device consists of a body part, an immobilization piece, and a bar-shaped weight.Assessment of locomotor activity, tissue damage, and macrophage infiltration confirmed the capability of the new SCI method.Reduction of adverse spinal movements and working without any accessory elements are the key points of this new animal model of SCI. Plain Language Summary: Spinal Cord Injury (SCI) is a medical problem that can cause the permanent motor and sensory dysfunction. Traffic accidents, falls, and violence are the most frequent causes of SCI, often affecting young people. Patients and even their families may encounter other problems, including reducing life quality, psychological burden, and enormous medical costs. Despite scientific and technological advances, no effective treatment has been found for SCI. Therefore, animal models help study damage mechanisms and evaluate novel treatment strategies. All SCI research centers require an economical and reproducible device without using complex surgical procedures by experienced surgeons to minimize variations in damage to the spinal cord. In this study, a simple, cheap, and reproducible novel instrument for SCI induction is introduced. The instrument consists of various parts, including a body part, an immobilization piece, and a bar-shaped weight. An 8-g weight was used for 5, 10, or 15 minutes to inflict injury to the spinal cord. Behavioral and tissue studies indicated that SCI could be induced in rodents in different severity without other elements. This instrument can be used in future investigations for SCI studies, including tissue engineering, stem cell therapy, and drugs delivery to access effective treatment.

Indexed as

Animal modelsMiceSpinal cord injury

Identifiers

PMID36589023
PMCPMC9790099
OpenAlexW3173792650

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.