ArticleHeart rhythm O22022
Left bundle branch pacing-optimized implantable cardioverter-defibrillator (LOT-ICD) for cardiac resynchronization therapy: A pilot study.
Article in Heart rhythm O2, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06745778 (Evolution of Intracardiac Electrograms Recorded by Left Bundle Branch Pacing Lead in Patients With ICD or CRT-D), which is not on this map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Evolution of Intracardiac Electrograms Recorded by Left Bundle Branch Pacing Lead in Patients With ICD or CRT-D
Who cites it
11 citing papers in PubMed, 22 citations in OpenAlex.
- Left Bundle Branch Area Pacing with a Defibrillator Lead in a Patient with Recurrent Ventricular Tachycardia and Severe Nonischemic Cardiomyopathy: A Case Report.The Journal of innovations in cardiac rhythm management · 2026Article
- Cost-effective CRT using dual-chamber generators in patients without atrial pacing need.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026Article
- [ICD electrode implantation for left bundle branch area pacing].Herzschrittmachertherapie & Elektrophysiologie · 2025Review
- Letter to the Editor: Building on Promising Evidence for Dual-Chamber ICDs in LBBAP.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2025Article
- Left bundle branch pacing in patients with structural heart disease: personalizing cardiac resynchronization therapy.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Review
- European Society of Cardiology (ESC) clinical consensus statement on indications for conduction system pacing, with special contribution of the European Heart Rhythm Association of the ESC and endorsed by the Asia Pacific Heart Rhythm Society, the Canadian Heart Rhythm Society, the Heart Rhythm Society, and the Latin American Heart Rhythm Society.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Article
- Evaluating the efficacy, safety, and predictors of failure following cardiac resynchronization therapy in a developing country: an ambispective, multi-center study.Cardiovascular diagnosis and therapy · 2025Article
- Is conduction system pacing a panacea for pacemaker therapy?Expert review of medical devices · 2024Review
- Conduction system pacing and defibrillation support using a single-chamber defibrillator - A case report.Journal of cardiology cases · 2023Article
- Introducing the 2023 HRS/APHRS/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure: Are we entering a new age in pacing?Heart rhythm O2 · 2023Article
- Special issue on electrophysiology and arrhythmia management around the globe: Challenges and opportunities explored.Heart rhythm O2 · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Left bundle branch pacing (LBBP) involves direct capture of left bundle fibers by placing the lead deep inside the interventricular septum. Several studies have shown the feasibility and efficacy of LBBP as an alternative modality for cardiac resynchronization therapy (CRT). This paper describes approach for providing cost effective CRT with defibrillator (CRT-D) by LBBP and dual chamber implantable cardioverter defibrillator (ICD) which we label as LBBP optimized ICD (LOT-ICD). LBBP was performed using C315 sheath and 3830 Selectsecure lead in all patients by premature ventricular complex guided approach. In patients with complete correction of conduction system disease, IS-1 connector plug of the IS-1/DF-1 lead was capped and 3830 lead connected to the dual chamber ICD pulse-generator at RV-P/S port. LOT-ICD provided stable R-wave sensing for arrhythmia monitoring and resulted in cost-effective resynchronization therapy at reduced fluoroscopy duration and radiation dose.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.