Safety and effectiveness of very-high-power, short-duration ablation in patients with atrial fibrillation: Preliminary results.

Karolina Mitrzak, Michał Peller, Bartosz Krzowski, Cezary Maciejewski, Paweł Balsam, Michał Marchel, Marcin Grabowski, Piotr Lodziński

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in Cardiology journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Karolina Mitrzak1st Department of Cardiology, Medical University of Warsaw, Poland. mitrzakkarolina@gmail.com.
Michał Peller1st Department of Cardiology, Medical University of Warsaw, Poland.
Bartosz Krzowski1st Department of Cardiology, Medical University of Warsaw, Poland.
Cezary Maciejewski1st Department of Cardiology, Medical University of Warsaw, Poland.
Paweł Balsam1st Department of Cardiology, Medical University of Warsaw, Poland.
Michał Marchel1st Department of Cardiology, Medical University of Warsaw, Poland.
Marcin Grabowski1st Department of Cardiology, Medical University of Warsaw, Poland.
Piotr Lodziński1st Department of Cardiology, Medical University of Warsaw, Poland.
Medical University of Warsaw · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPulmonary vein isolation (PVI) is at the forefront of rhythm control strategies in patients with atrial fibrillation (AF). A very-high-power, short-duration (vHPSD) catheter, QDot MicroTM (Biosense Webster) was designed to improve the effectiveness of AF ablation within a shorter procedure time. The aim of this study was to compare the effectiveness and safety of PVI ablation between this vHPSD ablation mode and conventional ablation-index-guided ablation (ThermoCool Smarttouch SF catheter).

methodsThis single-center, retrospective, observational study enrolled 108 patients with AF, referred for catheter ablation between December 16, 2019 and December 3, 2021. In 54 procedures (mean age: 58.0 ± 12.3; 66.67% male), a QDot MicroTM catheter was used (vHPSD-group), and 54 patients (mean age: 57.2 ± 11.8; 70.37% male) were treated with a ThermoCool SmarttouchTM SF catheter (AI-group). The primary endpoint was freedom from AF 3 months after ablation.

resultsAtrial fibrillation was found to recur in 14.81% of patients in the vHPSD-group and in 31.48% of patients in the AI-group (p = 0.07). There was no difference in treatment-emergent adverse events between the two groups (6.3% vs. 0%; p = 0.10). One severe adverse event (a cerebral vascular accident) was observed in the vHPSD-group. The mean dose of remifentanil was reported to be lower during QDot MicroTM catheter-based PVI (p < 0.01). The vHPSD-based PVI was associated with shorter radiofrequency application time (p < 0.001), fluoroscopy time (p < 0.0001), and total procedure time (p < 0.0001).

conclusionsThis study suggests vHPSD ablation is safe, can reduce the dosage of analgesics during significantly shorter procedures and may enhance the success rate of catheter-based PVI.

Indexed as

Atrial FibrillationCatheter AblationPulmonary VeinsAgedCardiac CathetersEquipment DesignFemaleFollow-Up StudiesHeart RateHumansMaleMiddle AgedRecurrenceRetrospective StudiesTime FactorsTreatment Outcomeablationatrial fibrillationpulmonary vein isolationQDot MicroTMvHPSD

Identifiers

PMID36588315
PMCPMC11374326
OpenAlexW4313424407

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.