Evidence map›Paper›PMID 36588207›Full record

ArticleIndian journal of ophthalmology2023

Effect of pupil dilation on biometric iris recognition systems for personal authentication.

Tanushree Singh, Simi Zaka-Ur-Rab, Shazia Arrin

Abstract read
In one paragraph

Article in Indian journal of ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Tanushree SinghInstitute of Ophthalmology, Jawaharlal Nehru Medical College and Hospital, Aligarh Muslim University, Aligarh, Uttar Pradesh, India.
Simi Zaka-Ur-RabInstitute of Ophthalmology, Jawaharlal Nehru Medical College and Hospital, Aligarh Muslim University, Aligarh, Uttar Pradesh, India.
Shazia ArrinInstitute of Ophthalmology, Jawaharlal Nehru Medical College and Hospital, Aligarh Muslim University, Aligarh, Uttar Pradesh, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To study the effect of pupil dilation on a biometric iris recognition (BIR) system for personal authentication and identification. Methods: A prospective, non-randomized, single-center cohort study was conducted on patients who reported for a routine eye check-up from November 2017 to November 2019 (2 years). An iris scanning device "IRITECH-MK2120U" was used to initially enroll the undilated eyes. Baseline scans were taken after matching with the enrolled database. All eyes were topically dilated and matched again with the enrolled database. The Hamming distance (a measure of disagreement between two iris codes) and recognition status were recorded from the device output, and eyes were evaluated by slit-lamp ophthalmoscopy with special emphasis on pupil shape, size, and texture. Results: All 321 enrolled eyes matched after topical dilation. The pupil size had a significant effect on Hamming distance with a P value <0.05. There were no false matches. A correct recognition rate of 100% was obtained after dilation. No loss of iris texture or pupil shape was observed after dilation. Conclusion: A BIR system is a reliable method for identification and personal authentication after pupil dilation. Topically dilated pupils are not a cause for non-recognition of iris scans.

Indexed as

BiometryPupilCohort StudiesHumansIrisProspective StudiesBiometryiris patterniris recognitionpupil dilation

Identifiers

PMID36588207
PMCPMC10155559

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.