ArticleHeart rhythm2023
Cardiovascular implantable electronic device lead safety: Harnessing real-world remote monitoring data for medical device evaluation.
Article in Heart rhythm, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 8 citations in OpenAlex.
Corrections and comments
- Commented on by
Authors and funding
12 authors at 6 institutions in 1 country.
Funding
Abstract
backgroundCurrent methods to identify cardiovascular implantable electronic device lead failure include postapproval studies, which may be limited in scope, participant numbers, and attrition; studies relying on administrative codes, which lack specificity; and voluntary adverse event reporting, which cannot determine incidence or attribution to the lead.
objectiveThe purpose of this study was to determine whether adjudicated remote monitoring (RM) data can address these limitations and augment lead safety evaluation.
methodsAmong 48,191 actively monitored patients with a cardiovascular implantable electronic device, we identified RM transmissions signifying incident lead abnormalities and, separately, identified all leads abandoned or extracted between April 1, 2019, and April 1, 2021. We queried electronic health record and Medicare fee-for-service claims data to determine whether patients had administrative codes for lead failure. We verified lead failure through manual electronic health record review.
resultsOf the 48,191 patients, 1170 (2.4%) had incident lead abnormalities detected by RM. Of these, 409 patients had administrative codes for lead failure, and 233 of these 409 patients (57.0%) had structural lead failure verified through chart review. Of the 761 patients without administrative codes, 167 (21.9%) had structural lead failure verified through chart review. Thus, 400 patients with RM transmissions suggestive of lead abnormalities (34.2%) had structural lead failure. In addition, 200 patients without preceding abnormal RM transmissions had leads abandoned or extracted for structural failure, making the total lead failure cohort 600 patients (66.7% with RM abnormalities, 33.3% without). Patients with isolated right atrial or left ventricular lead failure were less likely to have lead replacement and administrative codes reflective of lead failure.
conclusionRM may strengthen real-world assessment of lead failure, particularly for leads where patients do not undergo replacement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.