ArticleJournal of applied clinical medical physics2023
Feasibility and efficacy of active breathing coordinator assisted deep inspiration breath hold technique for treatment of locally advanced breast cancer.
Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 6 citations in OpenAlex.
- ACPSEM guideline: commissioning and quality assurance of Magnetic Resonance Imaging Linear Accelerators.Physical and engineering sciences in medicine · 2026Article
- Study on the application of thermo-optical surface monitoring + X-ray guidance system in DIBH for breast cancer.Frontiers in oncology · 2026Article
- Affordable realtime respiratory monitoring system for radiation oncology.Journal of applied clinical medical physics · 2025Article
- Systematic review of the tools and outcomes for the assessment of acute radiation dermatitis severity.Clinical and translational radiation oncology · 2025Review
- Feasibility and efficacy of active breathing coordinator assisted deep inspiration breath hold technique for treatment of locally advanced breast cancer.Journal of applied clinical medical physics · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 4 institutions in 1 country.
Funding
Abstract
backgroundActive breathing coordinator (ABC)-assisted deep inspiration breath hold (DIBH) is an important organ sparing radiation therapy (RT) technique for left-sided breast cancer patients. Patients with advanced breast cancer undergoing chest wall and regional nodal irradiation often require a field matching technique. While field matching has been demonstrated to be safe and effective in free breathing patients, its safety and accuracy in DIBH/ABC use has not been previously reported. PURPOSE: To report the accuracy, feasibility, and safety of field matching with ABC/DIBH for patients receiving breast/chest wall irradiation with nodal irradiation using a three-field technique.
methodsFrom December 2012 to May 2018, breast cancer patients undergoing ABC/DIBH-based RT at a single institution were reviewed. For each fraction, the amount of overlap/gap between the supraclavicular and the tangential field were measured and recorded. Patient characteristics, including acute and delayed skin toxicities, were analyzed.
resultsA total of 202 patients utilized ABC/DIBH and 4973 fractions had gap/overlap measurements available for analysis. The average gap/overlap measured at junction was 0.28 mm ± 0.99 mm. A total of 72% of fractions had no measurable gap/overlap (0 mm), while 5.6% had an overlap and 22.7% a gap. There was no significant trend for worsening or improvement of gap/overlap measurements with increasing fraction number per patient. OSLD measurements were compared to the planned dose. The median dose 1 cm above the junction was 106% ± 7% of planned dose (range 94%-116%). One centimeter below the junction, the median dose was 114% ± 11% of planned dose (range 95%-131%). At the junction, the median dose was 106% ± 16.3% of planned dose (range 86%-131%). Acute skin toxicity was similar to historically reported values (grade 3, 5.4%, grade 4, 0%).
conclusionABC-assisted DIBH is a safe and technically feasible method of delivering RT in the setting of complex matching field technique for breast and regional nodal treatments.
Indexed as