Evidence map›Paper›PMID 36585844›Full record

ArticleJournal of applied clinical medical physics2023

Extending the Eclipse

Ning Genevieve Wu

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Extending the EclipseJournal of applied clinical medical physics · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Ning Genevieve WuDepartment of Radiation Medicine, Oregon Health and Science University, Portland, Oregon, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate the necessity of extending the output factor table (OF Table) of the Varian Eclipse

methodsA new AcurosXB 15.6 beam model was created in the Eclipse Beam Configuration, which is identical to the one that has been used in the clinic with a default 3 × 3 cm to 40 × 40 cm OF Table, except the OF Table in the new model was extended to cover the range from 1 × 1 cm to 40 × 40 cm. 80 small square and rectangular output factors were measured on a Varian TrueBeam utilizing a Standard Imaging Exradin W2-1×1 scintillator detector, inside a PTW BeamScan water tank with 95 cm SSD at 5 cm depth. Cerenkov contamination was corrected using a rectangular field method (2 cm × 15 cm field). Nine Radiosurgery plans with primary jaw setting ranging from 0.7 cm to 2.0 cm were evaluated by both beam models. The monitor unit (MU) differences between the two beam models were calculated for identical 3-dimensional (3D) absolute dose distributions. Output factors, measured versus Eclipse calculated, were compared down to 0.5 × 0.5 cm primary jaw setting.

resultsFor the 6FFF beam, the difference between the two beam models was ∼ 6% for 1 × 1 cm jaw settings and 4% at 1.5 × 1.5 cm, with the extended OF Table requiring higher MUs for the same dose prescription and same 3-dimensional isodose distribution. For the 6MV beam, the corresponding difference is ∼7.5% for 1 × 1 cm, 5% for 1.5 × 1.5 cm, and 3% for 2 × 2 cm jaw settings, with the extended OF Table requiring higher MUs. For jaw settings smaller than 1 × 1 cm, measured dose can be considerably smaller than Eclipse predicted dose, even with the OF Table extension. This is reflected by the fact that the output factor for 0.5 × 0.5 cm, calculated via Eclipse external beam, was more than 30% greater than that measured for both 6FFF and 6MV beams.

conclusionsEclipse does a satisfactory job for primary jaw sizes down to 2 cm. For jaw settings smaller than 1.5 cm, the OF Table in Eclipse should be extended to improve the dose calculation accuracy.

Indexed as

RadiosurgeryAlgorithmsHumansPhantoms, ImagingRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-AssistedWaterWaterEclipse small field dosimetrySmall Field Output Factor Measurement

Identifiers

PMID36585844
PMCPMC9859982

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.