ArticleBMC neurology2022
Normal parameters for diagnostic transcranial magnetic stimulation using a parabolic coil with biphasic pulse stimulation.
Article in BMC neurology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 8 citations in OpenAlex.
- Corticospinal conduction in RFC1-related disease: a transcranial magnetic stimulation study.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2026Article
- Article
- Mu-Rhythm Phase Modulates Cortical Reactivity to Subthreshold TMS: A TMS-EEG Study.Bioengineering (Basel, Switzerland) · 2026Article
- [Repetitive transcranial magnetic stimulation for unipolar depression].Der Nervenarzt · 2026Review
- Hebbian plasticity induced by temporally coincident BCI enhances post-stroke motor recovery.Scientific reports · 2024Article
- Article
- Intermittent tetraburst stimulation combined with transcranial direct current stimulation once weekly for treatment-resistant depression: a case report.Journal of medical case reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
backgroundTMS is being used to aid in the diagnosis of central nervous system (CNS) illnesses. It is useful in planning rehabilitation programs and setting appropriate goals for patients. We used a parabolic coil with biphasic pulse stimulation to find normal values for diagnostic TMS parameters.
objectives1. To determine the normal motor threshold (MT), motor evoked potentials (MEP), central motor conduction time (CMCT), intracortical facilitation (ICF), short-interval intracortical inhibition (SICI), and silent period (SP) values. 2. To measure the MEP latencies of abductor pollicis brevis (APB) and extensor digitorum brevis (EDB) at various ages, heights, and arm and leg lengths. STUDY
designDescriptive Study.
settingDepartment of Rehabilitation Medicine, Chiang Mai University, Thailand. SUBJECTS: Forty-eight healthy participants volunteered for the study.
methodsAll participants received a single diagnostic TMS using a parabolic coil with biphasic pulse stimulation on the left primary motor cortex (M1). All parameters: MT, MEP, CMCT, ICF, SICI, and SP were recorded through surface EMGs at the right APB and EDB. Outcome parameters were reported by the mean and standard deviation (SD) or median and interquartile range (IQR), according to data distribution. MEP latencies of APB and EDB were also measured at various ages, heights, and arm and leg lengths.
resultsAPB-MEP latencies at 120% and 140% MT were 21.77 ± 1.47 and 21.17 ± 1.44 ms. APB-CMCT at 120% and 140% MT were 7.81 ± 1.32 and 7.19 ± 1.21 ms. APB-MEP amplitudes at 120% and 140% MT were 1.04 (0.80-1.68) and 2.24 (1.47-3.52) mV. EDB-MEP latencies at 120% and 140% MT were 37.14 ± 2.85 and 36.46 ± 2.53 ms. EDB-CMCT at 120% and 140% MT were 14.33 ± 2.50 and 13.63 ± 2.57 ms. EDB-MEP amplitudes at 120% and 140% MT were 0.60 (0.38-0.98) and 0.95 (0.69-1.55) mV. ICF amplitudes of APB and EDB were 2.26 (1.61-3.49) and 1.26 (0.88-1.98) mV. SICI amplitudes of APB and EDB were 0.21 (0.13-0.51) and 0.18 (0.09-0.29) mV. MEP latencies of APB at 120% and 140% MT were different between heights < 160 cm and ≥ 160 cm (p < 0.001 and p < 0.001) and different between arm lengths < 65 and ≥ 65 cm (p = 0.022 and p = 0.002).
conclusionWe established diagnostic TMS measurements using a parabolic coil with a biphasic pulse configuration. EDB has a higher MT than APB. The 140/120 MEP ratio of APB and EDB is two-fold. The optimal MEP recording for APB is 120%, whereas EDB is 140% of MT. CMCT by the F-wave is more convenient and tolerable for patients. ICF provides a twofold increase in MEP amplitude. SICI provides a ¼-fold of MEP amplitude. SP from APB and EDB are 121.58 ± 21.50 and 181.01 ± 40.99 ms, respectively. Height and MEP latencies have a modest relationship, whereas height and arm length share a strong positive correlation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.