Evidence map›Paper›PMID 36583933›Full record

ArticleJMIR formative research2022

Pilot Evaluation of Possible Airborne Transmission in a Geriatric Care Facility Using Carbon Dioxide Tracer Gas: Case Study.

Yo Ishigaki, Shinji Yokogawa, Yuki Minamoto, Akira Saito, Hiroko Kitamura, Yuto Kawauchi

Abstract read
In one paragraph

Article in JMIR formative research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Estimation of air change rate by COEnvironmental and occupational health practice · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yo IshigakiGraduate School of Informatics and Engineering, University of Electro-communications, Tokyo, Japan.ORCID https://orcid.org/0000-0001-7284-0381
Shinji YokogawaGraduate School of Informatics and Engineering, University of Electro-communications, Tokyo, Japan.ORCID https://orcid.org/0000-0003-2956-3600
Yuki MinamotoSchool of Engineering, Tokyo Institute of Technology, Tokyo, Japan.ORCID https://orcid.org/0000-0002-6157-8370
Akira SaitoDepartment of Clinical Laboratory Medicine, Miyagi Anti-Tuberculosis Association, Miyagi, Japan.ORCID https://orcid.org/0000-0003-0202-7509
Hiroko KitamuraOccupational Health Training Center, University of Occupational and Environmental Health, Fukuoka, Japan.ORCID https://orcid.org/0000-0001-5106-7094
Yuto KawauchiGraduate School of Informatics and Engineering, University of Electro-communications, Tokyo, Japan.ORCID https://orcid.org/0000-0002-8607-5788

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAlthough several COVID-19 outbreaks have occurred in older adult care facilities throughout Japan, no field studies focusing on airborne infections within these settings have been reported. Countermeasures against airborne infection not only consider the air change rate (ACR) in a room but also the airflow in and between rooms. However, a specific method has not yet been established by Japanese public health centers or infectious disease-related organizations.

objectiveIn April 2021, 59 COVID-19 cases were reported in an older adult care facility in Miyagi, Japan, and airborne transmission was suspected. The objective of this study was to simultaneously reproduce the ACR and aerosol advection in this facility using the carbon dioxide (CO

methodsIn August 2021, CO

resultsThe ACR values at the time of the outbreak were estimated to be 2.0 to 6.8 h

conclusionsThe present results suggest that secondary infections can occur owing to aerosol advection driven by large-scale flow, even when the building design adheres to the ventilation guidelines established in Japan. Moreover, the CO

Indexed as

ACRairborne transmissionair change ratecare homeCFDcomputational fluid dynamicsmobile phonenursing homeventilation frequency

Identifiers

PMID36583933
PMCPMC9840100

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.