ArticleJournal of prosthetics and orthotics : JPO2022
Mechanically and physiologically optimizing prosthetic elevated vacuum systems in people with transtibial amputation: a pilot study.
Article in Journal of prosthetics and orthotics : JPO, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Frequent versus infrequent partial doffing in transtibial prosthesis users as a means to stabilize residual limb fluid volume.Clinical biomechanics (Bristol, Avon) · 2025Article
- Performance of an auto-adjusting prosthetic socket during walking with intermittent socket release.Journal of rehabilitation and assistive technologies engineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Introduction: The most suitable elevated vacuum (EV) pressure may differ for each individual prosthesis user depending on suspension needs, socket fit, prosthetic components, and health. Mechanical and physiological effects of EV were evaluated in an effort to determine the optimal vacuum pressure for three individuals. Methods: Instrumented EV sockets were created based on the participants' regular EV sockets. Inductive distance sensors were embedded into the wall of the socket at select locations to measure limb movement relative to the socket. Each participant conducted an activity protocol while limb movement, limb fluid volume, and user-reported comfort were measured at various socket vacuum pressure settings. Results: Increased socket vacuum pressure resulted in reduced limb-socket displacement for each participant; however, 81-93% of limb movement was eliminated by a vacuum pressure setting of 12 (approximately -9 inHg). Relative limb-socket displacement by sensor location varied for each participant, suggesting distinct differences related to socket fit or residual limb tissue content. The rate of limb fluid volume change and the change in socket comfort did not consistently differ with socket vacuum pressure, suggesting a more complex relationship unique to each individual. Conclusions: Practitioners may use individual responses to optimize socket vacuum pressure settings, balancing mechanical and physiological effects of EV for improved clinical outcomes.