ArticleTranslational vision science & technology2022
Ex Vivo Evaluation of a Pressure-Sensitive Device to Aid Big Bubble Intrastromal Dissection in Deep Anterior Lamellar Keratoplasty.
Article in Translational vision science & technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To develop and perform ex vivo testing for a device designed for semiquantitative determination of intracorneal dissection depth during big bubble (BB) deep anterior lamellar keratoplasty. Methods: A prototype device connected to a syringe and cannula was designed to determine depth of intrastromal placement based on air rebound pressure emitted by a software controlled generator. Ex vivo testing of the device was conducted on human corneas mounted on an artificial anterior chamber in three experiments: (1) cannula purposely introduced at different depths measured with anterior segment optical coherence tomography, (2) cannula introduced as per the BB technique, and (3) simulation of the BB technique guided by the device. Results: A positive pressure differential and successful BB were observed only when the cannula was positioned within 150 microns from the endothelial plane. In all successful BB cases (21/40), a repeatable increase in tissue rebound pressure was detected, which was not recorded in unsuccessful cases. The device was able to signal to the surgeon correct placement of the cannula (successful BB) in 16 of 17 cases and incorrect placement of the cannula (unsuccessful BB) in 8 of 8 cases (94.1% sensitivity, 100% specificity). Conclusions: In our ex vivo model, this novel medical device could reliably signal cannula positioning in the deep stroma for effective pneumatic dissection and possibly aid technical execution of BB deep anterior lamellar keratoplasty. Translational Relevance: A medical device that standardizes big bubble deep anterior lamellar keratoplasty could increase the overall success rate of the surgical procedure and aid popularization of deep anterior lamellar keratoplasty.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.