Evidence map›Paper›PMID 36580208›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

Design and path tracking control of a continuum robot for maxillary sinus surgery.

Yongfeng Cao, Zefeng Liu, Zheng Liu, Shuang Wang, Le Xie

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 7 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Yongfeng CaoSchool of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China.ORCID http://orcid.org/0000-0002-7157-5325
Zefeng LiuSchool of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China.
Zheng LiuSchool of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China.
Shuang WangSchool of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China.
Le XieSchool of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China. lexie@sjtu.edu.cn.ORCID http://orcid.org/0000-0001-8123-8464
Shanghai Jiao Tong University · CN

Funding

National Natural Science Foundation of China 61973211National Natural Science Foundation of China 62133009National Natural Science Foundation of China M-0221Science and Technology Commission of Shanghai Municipality 21550714200
6 · The paper itself

Abstract

purposeContinuum robots (CRs) have been developed for maxillary sinus surgery (MSS) in recent years. However, due to the anatomically curved and narrow pathway of the maxillary sinus and the deformable characteristics of the CR, it is still a challenge to accurately approach the target in the sinus. Thus, the CR-assisted MSS demands further research, whether in robotic system design or in reliable motion control.

methodsA continuum robotic system integrated with essential instruments and sensors for MSS is developed, and the path tracking control of the designed CR is studied. The differential kinematic model of the CR is constructed. By analyzing the potential problem of the traditional Jacobian-based control, an iterative Jacobian transpose-based closed-loop control method is proposed to improve the path tracking performance. To validate the design of the CR and the effectiveness of the proposed control scheme, different groups of experiments are performed.

resultsWith the proposed method, the path tracking performance of the CR is improved. Compared with the open-loop Jacobian transpose-based control method, the path tracking error of the proposed method is much less. The maxillary sinus phantom tests are conducted to verify the reachability of the designed CR. Given the reference path from the nostril to the target in the maxillary sinus phantom, experiments show a mean error of 0.96 mm.

conclusionsThe designed CR is slender, flexible, and able to smoothly approach the target in a tortuous and constrained environment without colliding with or damaging the surrounding tissue. The designed continuum robotic system and the proposed iterative Jacobian transpose-based closed-loop control strategy have great potential for MSS. The limitations of the proposed method are also discussed.

Indexed as

RoboticsRobotic Surgical ProceduresBiomechanical PhenomenaHumansMaxillary SinusPhantoms, ImagingContinuum robotIterative Jacobian transpose-based methodMaxillary sinus surgeryPath tracking control

Identifiers

PMID36580208
OpenAlexW4313278422

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked