Evidence map›Paper›PMID 36572963›Full record

Observational studyClinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis

Whole-blood Point-of-Care Activated Partial Thromboplastin Time Ratio (APR) is not Accurate Enough to Monitor Heparin Therapy in Patients with Severe Respiratory Failure Secondary to SARS-Cov-2 Infection Supported with Veno-Venous Extracorporeal Membrane Oxygenation (VV-ECMO).

Daniel Aston, Martin Besser, Ben Goddard, Nicholas Maggs, Hassan Ahmed, Florian Falter

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.1field-weighted citation impact, top 62% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Daniel AstonDepartment of Anaesthesia and Critical Care, Royal Papworth Hospital, Cambridge Biomedical Campus, Cambridge, UK.ORCID 0000-0001-6886-8111
Martin BesserDivision of Clinical Haematology and Blood Transfusion, Cambridge University Hospitals, Cambridge, UK.
Ben GoddardDepartment of Clinical Perfusion, Royal Papworth Hospital, Cambridge Biomedical Campus, Cambridge, UK.
Nicholas MaggsDepartment of Clinical Perfusion, Royal Papworth Hospital, Cambridge Biomedical Campus, Cambridge, UK.
Hassan AhmedDepartment of Anaesthesia and Intensive Care, 4472Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Florian FalterDepartment of Anaesthesia and Critical Care, Royal Papworth Hospital, Cambridge Biomedical Campus, Cambridge, UK.
Papworth Hospital · GBCambridge University Hospitals NHS Foundation Trust · GBLeeds Teaching Hospitals NHS Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Support with VV-ECMO requires anticoagulation with unfractionated heparin to prevent thrombotic complications. This must be monitored due to bleeding risk. A point-of-care (POC) method of testing aPTT and APR was evaluated for agreement with laboratory methods. In a prospective observational study, patients supported on VV-ECMO as a result of severe respiratory failure secondary to Covid-19 infection were given heparin as part of standard therapy. The aPTT was measured (i) at the bedside using the Hemochron Signature Elite device and (ii) at the hospital laboratory. Duplicate results were compared. Agreement between the POC and laboratory tests was poor, as assessed using the Bland-Altman method. The maximum difference between POC and laboratory methods was 133% and the minimum was 0%. Overall bias was 7.3% and limits of agreement were between -43.8% and 58.5%. Correlation increased when results were normalised to platelet count and creatinine. This POC test is insufficiently accurate for use as the primary method of heparin monitoring in patients requiring VV-ECMO for Covid-19. Platelets and renal function may influence the result of this whole blood POC test.

Indexed as

COVID-19Extracorporeal Membrane OxygenationRespiratory InsufficiencyAnticoagulantsHeparinHumansPartial Thromboplastin TimePoint-of-Care SystemsRetrospective StudiesSARS-CoV-2AnticoagulantsHeparinanticoagulantscoagulationheparinsSARS-CoV-2

Identifiers

PMID36572963
PMCPMC9806398
OpenAlexW4312399961

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.