Effect of thermal osteonecrosis around implants in the rat tibia: numerical and histomorphometric results in context of implant removal.

Kristian Kniha, Benita Hermanns-Sachweh, Faruk Al-Sibai, Reinhold Kneer, Stephan Christian Möhlhenrich, Marius Heitzer, Frank Hölzle, Ali Modabber

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Kristian KnihaDepartment of Oral and Cranio-Maxillofacial Surgery, University Hospital, RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany. kkniha@ukaachen.de.
Benita Hermanns-SachwehPrivate Institute for Implant Pathology, ZBMT, Campus Melaten, Pauwelsstaße 17, Aachen, Germany.
Faruk Al-SibaiInstitute of Heat and Mass Transfer, RWTH Aachen University, Augustinerbach 6, Aachen, Germany.
Reinhold KneerInstitute of Heat and Mass Transfer, RWTH Aachen University, Augustinerbach 6, Aachen, Germany.
Stephan Christian MöhlhenrichDepartment of Orthodontics, University of Witten/Herdecke, Alfred-Herrhausen Str. 45, 58455, Witten, Germany.
Marius HeitzerDepartment of Oral and Cranio-Maxillofacial Surgery, University Hospital, RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany.
Frank HölzleDepartment of Oral and Cranio-Maxillofacial Surgery, University Hospital, RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany.
Ali ModabberDepartment of Oral and Cranio-Maxillofacial Surgery, University Hospital, RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this rat study was to explore the feasibility of in vivo temperature thresholds affecting bone contact at the implant surface. Based on these data, thermal necrosis should be used for implant removal in the subsequent in vivo study. Rat tibiae of 48 animals at one site were randomly treated with heat or cold before implant insertion. Temperatures of 4 °C, 3 °C, 2 °C, 48 °C, 49 °C and 50 °C for a tempering time of 1 min were evaluated. Numerical simulations of the heat source-implant-bone system were carried out. Effects were assessed by histomorphometrical measurements. The results showed that the selected method of direct tempering using a tempering pin was suitable for maintaining a uniform layer around the pin. Starting at warm temperatures of 48 °C and rising to 50 °C, the BIC ratio revealed declining values and a significant difference was observed when comparing 50 °C to the control group (p = 0.03). However, there were no significant variations within the cold temperatures. This study pinpointed temperature discovered that could lead to the thermo-explantation and so that the number of samples used in future studies on temperature-induced bone necrosis can be reduced to a minimum. Significant BIC value reduction was seen at a temperature of 50 °C for 1 min.

Indexed as

Dental ImplantsOsteonecrosisAnimalsBone and BonesOsseointegrationProstheses and ImplantsRatsSurface PropertiesTibiaTitaniumDental ImplantsTitanium

Identifiers

PMID36564495
PMCPMC9789117

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.