ArticleSkeletal radiology2023
Assessing tophaceous spinal gout treatment response using dual-energy CT as a point-of-care imaging modality: case report.
Article in Skeletal radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 5 citations in OpenAlex.
- Axial gout diagnosed by dual-energy CT in a young normouricaemic man with recurrent nephrolithiasis: a case-based review.Rheumatology international · 2026Review
- Updates on the Applications of Spectral Computed Tomography for Musculoskeletal Imaging.Diagnostics (Basel, Switzerland) · 2024Review
- Tophaceous gouty arthritis with spondylolysis: a case report.Journal of surgical case reports · 2023Article
- Understanding spinal gout: A comprehensive study of 88 cases and their clinical implications.Journal of craniovertebral junction & spineReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We describe a case of chronic tophaceous gout affecting the spine, hands, elbows, feet, and knees in a 67-year-old man with serum urate levels at 549 µmol/L whose response to treatment was successfully mapped using dual-energy computed tomography (DECT). The patient presented with exacerbation of acute-on-chronic lumbar back pain. He had received a diagnosis of gout 3 years prior to this presentation yet was not on any urate-lowering therapy. The patient received febuxostat 80 mg and colchicine 0.3 mg once daily and underwent DECT to assess baseline monosodium urate (MSU) burden. At baseline, MSU deposits were seen in the hands, elbows, feet, knees, and lumbar spine including the left L5-S1 facet joint encroaching onto the neural foramen. After 2.5 years of treatment, serum urate level was within the target range (< 360 µmol/L), and the patient underwent a follow-up DECT that revealed almost full resolution of MSU deposition in the spine, including the MSU-burdened facet joint and neural foramen in the lumbar spine, in addition to all the affected peripheral joints. This case is the first report of radiological evidence of nearly complete resolution of MSU deposits in spinal gout on DECT after urate-lowering therapy treatment, which demonstrates the utility of this imaging modality as a non-invasive investigational point-of-care imaging modality for mapping treatment response and identifying the etiology of back pain in a patient with chronic tophaceous spinal gout.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.