ArticleAnalytical chemistry2023
Sensitive and Quantitative Point-of-Care HIV Viral Load Quantification from Blood Using a Power-Free Plasma Separation and Portable Magnetofluidic Polymerase Chain Reaction Instrument.
Article in Analytical chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 14 citations in OpenAlex.
- Centrifuge-free separation of plasma from milliliters of whole blood for point-of-care diagnostics.Lab on a chip · 2026Article
- Immunomagnetic Sample Preparation Targeting Host- and Viral-Derived Antigens for HIV-1 Isolation from Limited Plasma Volumes.Analytical chemistry · 2026Article
- Extraction-Free Scalable Sample Preparation for the Rapid Detection of HIV in Blood Plasma.Analytical chemistry · 2026Article
- A Portable Dual-Mode Microfluidic Device Integrating RT-qPCR and RT-LAMP for Rapid Nucleic Acid Detection in Point-of-Care Testing.Biosensors · 2026Article
- Emerging Microfluidic Plasma Separation Technologies for Point-of-Care Diagnostics: Moving Beyond Conventional Centrifugation.Biosensors · 2025Review
- Development of PCR, qPCR and LAMP methods for the detection ofFood and waterborne parasitology · 2025Article
- Thermally Responsive Alkane Partitions and a Magnetofluidic Assay for Point-of-Sample Detection of Viruses in Wastewater.Biosensors · 2025Article
- Stakeholder considerations on acceptability and implementation of a novel rapid test for acute HIV infection: A qualitative study in Indiana.PLOS global public health · 2025Article
- Sample-to-Answer Detection of SARS-CoV-2 Viremia Using Thermally Responsive Alkane Partitions.Analytical chemistry · 2024Article
- Palm-Sized Lab-In-A-Magnetofluidic Tube Platform for Rapid and Sensitive Virus Detection.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Article
- Stakeholder-engaged development of a rapid test for detection of acute HIV infection.Research square · 2024Article
- Compact Point-of-Care Device for Self-Administered HIV Viral Load Tests from Whole Blood.ACS sensors · 2023Article
- Streamlined instrument-free lysis for the detection of Candida auris.Scientific reports · 2023Article
- Programmable magnetic robot (ProMagBot) for automated nucleic acid extraction at the point of need.Lab on a chip · 2023Article
- Recent Advances in Molecular and Immunological Diagnostic Platform for Virus Detection: A Review.Biosensors · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
Abstract
Point-of-care (POC) HIV viral load (VL) tests are needed to enhance access to HIV VL testing in low- and middle-income countries (LMICs) and to enable HIV VL self-testing at home, which in turn have the potential to enhance the global management of the disease. While methods based on real-time reverse transcription-polymerase chain reaction (RT-PCR) are highly sensitive and quantitatively accurate, they often require bulky and expensive instruments, making applications at the POC challenging. On the other hand, although methods based on isothermal amplification techniques could be performed using low-cost instruments, they have shown limited quantitative accuracies, i.e., being only semiquantitative. Herein, we present a sensitive and quantitative POC HIV VL quantification method from blood that can be performed using a small power-free three-dimensional-printed plasma separation device and a portable, low-cost magnetofluidic real-time RT-PCR instrument. The plasma separation device, which is composed of a plasma separation membrane and an absorbent material, demonstrated 96% plasma separation efficiency per 100 μL of whole blood. The plasma solution was then processed in a magnetofluidic cartridge for automated HIV RNA extraction and quantification using the portable instrument, which completed 50 cycles of PCR in 15 min. Using the method, we achieved a limit of detection of 500 HIV RNA copies/mL, which is below the World Health Organization's virological failure threshold, and a good quantitative accuracy. The method has the potential for sensitive and quantitative HIV VL testing at the POC and at home self-testing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials