Evidence map›Paper›PMID 36560322›Full record

ArticleSensors (Basel, Switzerland)2022

A Differential Inertial Wearable Device for Breathing Parameter Detection: Hardware and Firmware Development, Experimental Characterization.

Roberto De Fazio, Maria Rosaria Greco, Massimo De Vittorio, Paolo Visconti

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Roberto De FazioDepartment of Innovation Engineering, University of Salento, 73100 Lecce, Italy.ORCID 0000-0003-0893-138X
Maria Rosaria GrecoDepartment of Innovation Engineering, University of Salento, 73100 Lecce, Italy.
Massimo De VittorioDepartment of Innovation Engineering, University of Salento, 73100 Lecce, Italy.
Paolo ViscontiDepartment of Innovation Engineering, University of Salento, 73100 Lecce, Italy.ORCID 0000-0002-4058-4042
University of Salento · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Breathing monitoring is crucial for evaluating a patient's health status. The technologies commonly used to monitor respiration are costly, bulky, obtrusive, and inaccurate, mainly when the user moves. Consequently, efforts have been devoted to providing new solutions and methodologies to overcome these limitations. These methods have several uses, including healthcare monitoring, measuring athletic performance, and aiding patients with respiratory diseases, such as COPD (chronic obtrusive pulmonary disease), sleep apnea, etc. Breathing-induced chest movements can be measured noninvasively and discreetly using inertial sensors. This research work presents the development and testing of an inertia-based chest band for breathing monitoring through a differential approach. The device comprises two IMUs (inertial measurement units) placed on the patient's chest and back to determine the differential inertial signal, carrying out information detection about the breathing activity. The chest band includes a low-power microcontroller section to acquire inertial data from the two IMUs and process them to extract the breathing parameters (i.e., RR-respiration rate; TI/TE-inhalation/exhalation time; IER-inhalation-to-exhalation time; V-flow rate), using the back IMU as a reference. A BLE transceiver wirelessly transmits the acquired breathing parameters to a mobile application. Finally, the test results demonstrate the effectiveness of the used dual-inertia solution; correlation and Bland-Altman analyses were performed on the RR measurements from the chest band and the reference, demonstrating a high correlation (r¯ = 0.92) and low mean difference (MD¯ = -0.27 BrPM (breaths per minute)), limits of agreement (LoA¯ = +1.16/-1.75 BrPM), and mean absolute error (MAE¯ = 1.15%). Additionally, the experimental results demonstrated that the developed device correctly measured the other breathing parameters (TI, TE, IER, and V), keeping an MAE of ≤5%. The obtained results indicated that the developed chest band is a viable solution for long-term breathing monitoring, both in stationary and moving users.

Indexed as

Sleep Apnea SyndromesWearable Electronic DevicesExhalationHumansRespirationRespiratory RateBland–Altman analysisbreathing parameterschest movementsdigital filteringinertial sensorswearable devices

Identifiers

PMID36560322
PMCPMC9787627
OpenAlexW4312210730

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked