Evidence map›Paper›PMID 36560297›Full record

ArticleSensors (Basel, Switzerland)2022

Fast Iterative Shrinkage-Thresholding Algorithm with Continuation for Brain Injury Monitoring Imaging Based on Electrical Impedance Tomography.

Xuechao Liu, Tao Zhang, Jian'an Ye, Xiang Tian, Weirui Zhang, Bin Yang, Meng Dai, Canhua Xu, Feng Fu

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Xuechao LiuDepartment of Biomedical Engineering, The Fourth Military Medical University, Xi'an 710032, China.ORCID 0000-0002-0358-0683
Tao ZhangDepartment of Biomedical Engineering, The Fourth Military Medical University, Xi'an 710032, China.ORCID 0000-0002-1535-4309
Jian'an YeDepartment of Biomedical Engineering, The Fourth Military Medical University, Xi'an 710032, China.ORCID 0000-0003-1968-7669
Xiang TianDepartment of Biomedical Engineering, The Fourth Military Medical University, Xi'an 710032, China.
Weirui ZhangDepartment of Biomedical Engineering, The Fourth Military Medical University, Xi'an 710032, China.
Bin YangDepartment of Biomedical Engineering, The Fourth Military Medical University, Xi'an 710032, China.
Meng DaiDepartment of Biomedical Engineering, The Fourth Military Medical University, Xi'an 710032, China.
Canhua XuDepartment of Biomedical Engineering, The Fourth Military Medical University, Xi'an 710032, China.
Feng FuDepartment of Biomedical Engineering, The Fourth Military Medical University, Xi'an 710032, China.
Air Force Medical University · CN

Funding

Natural Science Basic Research Program of Shaanxi 2022JQ-872Technology Field Foundation on Basic Strengthen Project 2019-JCJQ-JJ-096the Key Research and Development Program of Shaanxi 2022ZDLSF04-07The National Nature Science Foundation of China 31900978The National Nature Science Foundation of China 51837011
6 · The paper itself

Abstract

Electrical impedance tomography (EIT) is low-cost and noninvasive and has the potential for real-time imaging and bedside monitoring of brain injury. However, brain injury monitoring by EIT imaging suffers from image noise (IN) and resolution problems, causing blurred reconstructions. To address these problems, a least absolute shrinkage and selection operator model is built, and a fast iterative shrinkage-thresholding algorithm with continuation (FISTA-C) is proposed. Results of numerical simulations and head phantom experiments indicate that FISTA-C reduces IN by 63.2%, 47.2%, and 29.9% and 54.4%, 44.7%, and 22.7%, respectively, when compared with the damped least-squares algorithm, the split Bergman, and the FISTA algorithms. When the signal-to-noise ratio of the measurements is 80-50 dB, FISTA-C can reduce IN by 83.3%, 72.3%, and 68.7% on average when compared with the three algorithms, respectively. Both simulation and phantom experiments suggest that FISTA-C produces the best image resolution and can identify the two closest targets. Moreover, FISTA-C is more practical for clinical application because it does not require excessive parameter adjustments. This technology can provide better reconstruction performance and significantly outperforms the traditional algorithms in terms of IN and resolution and is expected to offer a general algorithm for brain injury monitoring imaging via EIT.

Indexed as

Brain InjuriesImage Processing, Computer-AssistedAlgorithmsElectric ImpedanceHumansPhantoms, ImagingTomographyTomography, X-Ray Computedbrain injury monitoring imagingelectrical impedance tomographyfast iterative shrinkage-thresholding algorithmleast absolute shrinkage and selection operator modelreconstruction algorithm

Identifiers

PMID36560297
PMCPMC9783778
OpenAlexW4312195590

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.