Evidence map›Paper›PMID 36560138›Full record

ArticleSensors (Basel, Switzerland)2022

A Transparent Teleoperated Robotic Surgical System with Predictive Haptic Feedback and Force Modelling.

Taran Batty, Armin Ehrampoosh, Bijan Shirinzadeh, Yongmin Zhong, Julian Smith

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Taran BattyAustralian Synchrotron, ANSTO, Melbourne, VIC 3168, Australia.
Armin EhrampooshRobotics and Mechatronics Research Laboratory (RMRL), Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC 3800, Australia.ORCID 0000-0002-5482-3454
Bijan ShirinzadehRobotics and Mechatronics Research Laboratory (RMRL), Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC 3800, Australia.ORCID 0000-0001-8474-5445
Yongmin ZhongDepartment of Mechanical and Automotive Engineering, RMIT University, Melbourne, VIC 3083, Australia.ORCID 0000-0002-0105-9296
Julian SmithDepartment of Surgery, Monash University, Melbourne, VIC 3800, Australia.ORCID 0000-0003-1244-4277

Funding

Australian Research Council Discovery Projects grants DP180103852Monash Institute of Medical Engineering (MIME) Seed Funding
6 · The paper itself

Abstract

In recent years, robotic minimally invasive surgery has transformed many types of surgical procedures and improved their outcomes. Implementing effective haptic feedback into a teleoperated robotic surgical system presents a significant challenge due to the trade-off between transparency and stability caused by system communication time delays. In this paper, these time delays are mitigated by implementing an environment estimation and force prediction methodology into an experimental robotic minimally invasive surgical system. At the slave, an exponentially weighted recursive least squares (EWRLS) algorithm estimates the respective parameters of the Kelvin-Voigt (KV) and Hunt-Crossley (HC) force models. The master then provides force feedback by interacting with a virtual environment via the estimated parameters. Palpation experiments were conducted with the slave in contact with polyurethane foam during human-in-the-loop teleoperation. The experimental results indicated that the prediction RMSE of error between predicted master force feedback and measured slave force was reduced to 0.076 N for the Hunt-Crossley virtual environment, compared to 0.356 N for the Kelvin-Voigt virtual environment and 0.560 N for the direct force feedback methodology. The results also demonstrated that the HC force model is well suited to provide accurate haptic feedback, particularly when there is a delay between the master and slave kinematics. Furthermore, a haptic feedback approach that incorporates environment estimation and force prediction improve transparency during teleoperation. In conclusion, the proposed bilateral master-slave robotic system has the potential to provide transparent and stable haptic feedback to the surgeon in surgical robotics procedures.

Indexed as

RoboticsSurgery, Computer-AssistedAlgorithmsFeedbackHaptic TechnologyHumansMinimally Invasive Surgical Proceduresforce modellinghaptic feedbackmedical roboticspredictive force feedbackteleoperated robotic surgery

Identifiers

PMID36560138
PMCPMC9780898

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.