Evidence map›Paper›PMID 36557981›Full record

ReviewMolecules (Basel, Switzerland)2022

A Review for In Vitro and In Vivo Detection and Imaging of Gaseous Signal Molecule Carbon Monoxide by Fluorescent Probes.

Can Xie, Kun Luo, Libin Tan, Qiaomei Yang, Xiongjie Zhao, Liyi Zhou

Abstract readReview
In one paragraph

Review in Molecules (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Can XieCollege of Food Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China.
Kun LuoCollege of Food Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China.
Libin TanCollege of Food Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China.
Qiaomei YangCollege of Food Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China.
Xiongjie ZhaoCollege of Chemistry and Bioengineering, Hunan University of Science and Engineering, Yongzhou 425199, China.
Liyi ZhouCollege of Food Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China.

Funding

Hunan Provincial Natural Science Foundation of China 2017JJ3060National Natural Science Foundation of China 21605046
6 · The paper itself

Abstract

Carbon monoxide (CO) is a vital endogenous gaseous transmitter molecule involved in the regulation of various physiological and pathological processes in living biosystems. In order to investigate the biological function of CO, many technologies have been developed to monitor the level of endogenous CO in biosystems. Among them, the fluorescence detection technology based on the fluorescent probe has the advantages of high sensitivity, excellent selectivity, simple operation, especially non-invasive damage to biological samples, and the possibility of real-time in situ detection, etc., which is considered to be one of the most effective and applicable detection techniques. Therefore, in the last few years, a lot of work has been carried out on the design, synthesis and in vivo fluorescence imaging studies of CO fluorescent probes. Furthermore, using fluorescent probes to detect the changes in CO concentrations in living cells and tissues as well as in organisms has been one of the hot research topics in recent years. However, it is still a challenge to rationally design CO fluorescent probe with excellent optical performance, structural stability, low background interference, good biocompatibility, and excellent water solubility. Therefore, this review focuses on the research progress of CO fluorescent probes in the detection mechanism and biological applications in recent years. However, this popular and leading topic has rarely been summarized comprehensively to date. Thus, the research progress of CO fluorescent probes in recent years is reviewed in terms of their design concept, detection mechanism, and their biological applications. In addition, the relationship between the structure and performance of the probes was also discussed. More significantly, we hope that more excellent optical properties fluorescent probes for gaseous transmitter molecule CO detection and imaging will overcome the current problems of high biotoxicity and limited water solubility in future.

Indexed as

Carbon MonoxideFluorescent DyesGasesOptical ImagingWaterCarbon MonoxideFluorescent DyesGasesWaterCarbon monoxidefluorescent probegaseous transmitter moleculeresponse mechanism

Identifiers

PMID36557981
PMCPMC9784967

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.