Evidence map›Paper›PMID 36557481›Full record

ArticleMicromachines2022

Fabrication, Acoustic Characterization and Phase Reference-Based Calibration Method for a Single-Sided Multi-Channel Ultrasonic Actuator.

Hiep Xuan Cao, Daewon Jung, Han-Sol Lee, Van Du Nguyen, Eunpyo Choi, Chang-Sei Kim, Jong-Oh Park, Byungjeon Kang

Abstract read
In one paragraph

Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hiep Xuan CaoSchool of Mechanical Engineering, Chonnam National University, Gwangju 61186, Republic of Korea.ORCID 0000-0002-0623-4807
Daewon JungKorea Institute of Medical Microrobotics, Gwangju 61011, Republic of Korea.
Han-Sol LeeSchool of Mechanical Engineering, Chonnam National University, Gwangju 61186, Republic of Korea.ORCID 0000-0002-8715-3274
Van Du NguyenSchool of Mechanical Engineering, Chonnam National University, Gwangju 61186, Republic of Korea.ORCID 0000-0001-5139-8491
Eunpyo ChoiSchool of Mechanical Engineering, Chonnam National University, Gwangju 61186, Republic of Korea.ORCID 0000-0002-9689-6520
Chang-Sei KimSchool of Mechanical Engineering, Chonnam National University, Gwangju 61186, Republic of Korea.ORCID 0000-0003-4532-2006
Jong-Oh ParkKorea Institute of Medical Microrobotics, Gwangju 61011, Republic of Korea.
Byungjeon KangKorea Institute of Medical Microrobotics, Gwangju 61011, Republic of Korea.ORCID 0000-0003-1185-1911

Funding

Ministry of Health and Welfare HI19C0642
6 · The paper itself

Abstract

The ultrasonic actuator can be used in medical applications because it is label-free, biocompatible, and has a demonstrated history of safe operation. Therefore, there is an increasing interest in using an ultrasonic actuator in the non-contact manipulation of micromachines in various materials and sizes for therapeutic applications. This research aims to design, fabricate, and characterize a single-sided transducer array with 56 channels operating at 500 kHz, which provide benefits in the penetration of tissue. The fabricated transducer is calibrated using a phase reference calibration method to reduce position misalignment and phase discrepancies caused by acoustic interaction. The acoustic fields generated by the transducer array are measured in a 300 mm × 300 mm × 300 mm container filled with de-ionized water. A hydrophone is used to measure the far field in each transducer array element, and the 3D holographic pattern is analyzed based on the scanned acoustic pressure fields. Next, the phase reference calibration is applied to each transducer in the ultrasonic actuator. As a result, the homogeneity of the acoustic pressure fields surrounding the foci area is improved, and the maximum pressure is also increased in the twin trap. Finally, we demonstrate the capability to trap and manipulate micromachines with acoustic power by generating a twin trap using both optical camera and ultrasound imaging systems in a water medium. This work not only provides a comprehensive study on acoustic actuators but also inspires the next generation to use acoustics in medical applications.

Indexed as

phase calibrationtwin trapultrasonic actuators

Identifiers

PMID36557481
PMCPMC9782305

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.