Evidence map›Paper›PMID 36556844›Full record

ArticleMaterials (Basel, Switzerland)2022

A Biomechanical Analysis of the Influence of the Morfology of the Bone Blocks Grafts on the Transfer of Tension or Load to the Soft Tissue by Means of the Finite Elements Method.

Blanca Gil-Marques, Antonio Pallarés-Sabater, Aritza Brizuela-Velasco, Fernando Sánchez Lasheras, Pedro Lázaro-Calvo, María Dolores Gómez-Adrián, Carolina Larrazábal-Morón

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Blanca Gil-MarquesDoctoral School, Catholic University of Valencia San Vicente Mártir, 46001 Valencia, Spain.ORCID 0000-0003-0345-3585
Antonio Pallarés-SabaterDepartament Endodonthics, School of Dentistry, Catholic University of Valencia San Vicente Mártir, 46001 Valencia, Spain.
Aritza Brizuela-VelascoDepartament of Dentistry, Universidad Europea Miguel de Cervantes, 47012 Valladolid, Spain.ORCID 0000-0001-6421-3863
Fernando Sánchez LasherasDepartment of Mathematics, Faculty of Sciences, University of Oviedo, 33007 Oviedo, Spain.ORCID 0000-0002-7052-2811
Pedro Lázaro-CalvoDepartament of Periodonticx, Complutense University, 28004 Madrid, Spain.
María Dolores Gómez-AdriánSchool of Dentistry, Departament Medical and Surgery, Catholic University of Valencia San Vicente Mártir, 46001 Valencia, Spain.ORCID 0000-0003-0914-3596
Carolina Larrazábal-MorónSchool of Dentistry, Departament Medical and Surgery, Catholic University of Valencia San Vicente Mártir, 46001 Valencia, Spain.ORCID 0000-0002-4696-5698
Universitat de València · ESInstitute of Space Sciences · ESUniversidad Complutense de Madrid · ESUniversidad Europea Miguel de Cervantes · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Edentulism produces resorption of alveolar bone processes, which can complicate placement of dental implants. Guided bone regeneration techniques aim to recover the volume of bone. These treatments are susceptible to the surgical technique employed, the design of the autologous block or the tension of the suture. These factors can relate to major complications as the lack of primary closure and dehiscence. The present study, using finite element analysis, aimed to determine differences in terms of displacement of the oral mucosa, transferred stress according to Von Mises and deformation of soft tissue when two block graft designs (right-angled and rounded) and two levels of suture tension (0.05 and 0.2 N) were combined. The results showed that all the variables analyzed were greater with 0.2 N. Regarding the design of the block, no difference was found in the transferred stress and deformation of the soft tissue. However, displacement was related to a tendency to dehiscence (25% greater in the right-angled/chamfer design). In conclusion different biomechanical behavior was observed in the block graft depending on the design and suture tension, so it is recommended to use low suture tension and rounded design. A novel finite element analysis model is presented for future investigations.

Indexed as

finite element analysisoral bone blockprimary wound closureregenerative oral surgerysplit bone blockwound dehiscence

Identifiers

PMID36556844
PMCPMC9786190
OpenAlexW4312210027

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.