Evidence map›Paper›PMID 36556315›Full record

ArticleLife (Basel, Switzerland)2022

A Retrospective, Observational Study of Catheter-Associated Urinary Tract Infection Events Post-Implementation of a Novel Urinary Catheter System with Active Drain Line Clearance and Automated Intra-Abdominal Pressure Monitoring.

Patrick Brockway, David M Hill, Vanessa Moll, Kelly Stanton, Manu L N G Malbrain, Sai R Velamuri

Open access · goldAbstract read
In one paragraph

Article in Life (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Patrick BrockwayFirefighters Burn Center, Regional One Health, Memphis, TN 38103, USA.ORCID 0000-0002-8376-879X
David M HillFirefighters Burn Center, Regional One Health, Memphis, TN 38103, USA.ORCID 0000-0002-1119-1901
Vanessa MollDepartment of Anesthesiology, Division of Critical Care Medicine, Emory University School of Medicine, Atlanta, GA 30322, USA.ORCID 0000-0001-6092-0202
Kelly StantonPotrero Medical, Hayward, CA 94545, USA.ORCID 0000-0002-0707-5457
Manu L N G MalbrainFirst Department of Anesthesiology and Intensive Therapy, Medical University Lublin, 20-954 Lublin, Poland.ORCID 0000-0002-1816-5255
Sai R VelamuriFirefighters Burn Center, Regional One Health, Memphis, TN 38103, USA.
Regional Medical Center · USEmory University · USMedical University of Lublin · PLPotrero Medical (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: A quality improvement study to assess catheter-associated urinary tract infection (CAUTI) rate post-implementation of a bladder catheter with integrated active drain line urine clearance and automated intra-abdominal pressure monitoring in a burn intensive care unit (ICU).

designEight-year retrospective before and after study (2015−2022). Setting: A single American Burn Association-verified Burn Center with 14 inpatient beds. Patients: Patients meeting criteria for admission to a Burn Center. Methods: Retrospective cohort study following the implementation of a novel urine output monitoring system with integrated drain line and urine clearance. Data from a 48-month (from January 2015−December 2018) historical control (period 1) were compared to data from a 28-month (from January 2020 to April 2022) post-implementation period (period 2). Pre- and post-implementation CAUTI event incidences were compared. Patients were transferred from outside hospitals with gravity bladder. A distinction in the chart between catheter types was impossible. Charts were reviewed to characterize patients with CAUTI events. Results: A total of 42 CAUTIs in 2243 patients were identified using the National Health and Safety Network (NHSN) definition during the analyzed period. There were 40 CAUTI events in period 1 and two CAUTIs in period 2. The incidence of CAUTI events pre-implementation was 0.030 (mean of 10 CAUTI events per year) compared to 0.002 (mean of 1 CAUTI event per year) post-implementation of an automatic drain line clearing UO monitoring system showing a significant reduction in CAUTI events (p < 0.01, risk ratio novel vs. gravity bladder catheter 0.071, 95% confidence interval: 0.017−0.294). Conclusions: CAUTIs were reduced in the period following the implementation of a novel urinary catheter system with an integrated active drain line and urine clearance in burn patients.

Indexed as

active drain line clearanceburnscatheter-associated infectionCAUTIhealthcare-associated infectionintra-abdominal pressuremeasurementurinary tract infection

Identifiers

PMID36556315
PMCPMC9782014
OpenAlexW4309685835

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.