Evidence map›Paper›PMID 36554480›Full record

ArticleInternational journal of environmental research and public health2022

Analysis of the Interior Microclimate in Art Nouveau Heritage Buildings for the Protection of Exhibits and Human Health.

Alexandru Ilieș, Tudor Caciora, Florin Marcu, Zharas Berdenov, Gabriela Ilieș, Bahodirhon Safarov, Nicolaie Hodor, Vasile Grama, Maisa Ali Al Shomali, Dorina Camelia Ilies and 3 more

Open access · goldAbstract read
In one paragraph

Article in International journal of environmental research and public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
16.8field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 6 institutions in 5 countries.

Alexandru IlieșDepartment of Geography, Tourism and Territorial Planning, Faculty of Geography, Tourism and Sport, University of Oradea, 1 Universitatii Street, 410087 Oradea, Romania.
Tudor CacioraDepartment of Geography, Tourism and Territorial Planning, Faculty of Geography, Tourism and Sport, University of Oradea, 1 Universitatii Street, 410087 Oradea, Romania.
Florin MarcuFaculty of Medicine and Pharmacy, University of Oradea, 10 Piata, 1 Decembrie Street, 410073 Oradea, Romania.
Zharas BerdenovFaculty of Science, L.N. Gumilyov Eurasian National University, 2 Satpayev Street, Nur-Sultan 010008, Kazakhstan.ORCID 0000-0002-2898-8212
Gabriela IlieșFaculty of Geography, Babes-Bolyai University, Sighetu Marmatiei Extension, 6 Avram Iancu Street, 435500 Sighetu Marmatiei, Romania.
Bahodirhon SafarovDepartment of Digital Economy, Samarkand State University, Samarkand 140104, Uzbekistan.ORCID 0000-0002-2736-7000
Nicolaie HodorFaculty of Geography, Babes-Bolyai University, 5-6 Clinicilor Street, 400006 Cluj-Napoca, Romania.
Vasile GramaDepartment of Geography, Tourism and Territorial Planning, Faculty of Geography, Tourism and Sport, University of Oradea, 1 Universitatii Street, 410087 Oradea, Romania.ORCID 0000-0003-0600-1138
Maisa Ali Al ShomaliFaculty of Engineering, Al-Balqa Applied University, P.O. Box 15008, Marka 11134, Jordan.
Dorina Camelia IliesDepartment of Geography, Tourism and Territorial Planning, Faculty of Geography, Tourism and Sport, University of Oradea, 1 Universitatii Street, 410087 Oradea, Romania.
Ovidiu GaceuDepartment of Geography, Tourism and Territorial Planning, Faculty of Geography, Tourism and Sport, University of Oradea, 1 Universitatii Street, 410087 Oradea, Romania.
Monica CosteaFaculty of Environmental Protection, University of Oradea, Gen Magheru Street, 410048 Oradea, Romania.
Damiannah KietiSchool of Tourism, Hospitality & Events Management, Department of Tourism, Moi University, Kesses, Eldoret 3900-30100, Kenya.
University of Oradea · ROBabeș-Bolyai University · ROAl-Balqa Applied University · JOL. N. Gumilyov Eurasian National University · KZMoi University · KESamarkand State University named after Sharof Rashidov · UZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Poor air quality inside museums can have a double effect; on the one hand, influencing the integrity of the exhibits and on the other hand, endangering the health of employees and visitors. Both components can be very sensitive to the influence of the internal microclimate, therefore careful monitoring of the physical parameters and pollutants is required in order to maintain them within strict limits and thus to reduce the hazards that can be induced. The current study considers the determination and analysis of 15 indicators of the internal microclimate in an Art Nouveau museum built at the beginning of the 20th century in the Municipality of Oradea, Romania. The monitoring spanned a period of seven months, between September 2021 and March 2022, targeting three rooms of the museum with different characteristics and containing exhibits with a high degree of fragility. The results show that, although there are numerous indicators that have exceeded the thresholds induced by international standards, the possible negative impact on the exhibits and/or on human health remains moderate. This is due to the fact that, most of the time, exceeding the permitted limits are small or only sporadic, the values quickly returning to the permitted limits. Thus, only 22 of the 212 days of monitoring recorded marginal conditions regarding the quality of the indoor air, the rest having acceptable and good conditions. To improve the indoor conditions, a more careful management is needed, especially regarding the values of temperature, humidity, particulate matters, natural and artificial light, volatile organic compounds (VOC) and formaldehyde (HCHO), which during the measurements recorded high values that fluctuated in a wide spectrum. The obtained results can represent the basis for the development and implementation of long-term strategies for stabilizing the microclimatic conditions in the museum in order to preserve the exhibits preventively and to ensure a clean and safe environment for people.

Indexed as

Air PollutantsAir PollutionAir Pollution, IndoorEnvironmental MonitoringHumansMicroclimateParticulate MatterAir PollutantsParticulate Mattercultural heritagehuman healthindoor air qualitymuseum microclimatepollutantspreventive conservationrisk assessment

Identifiers

PMID36554480
PMCPMC9779619
OpenAlexW4312124039

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.