Evidence map›Paper›PMID 36553219›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Computer-Aided Assessment of Three-Dimensional Standard Bone Morphology of the Distal Radius.

Akira Ikumi, Yuichi Yoshii, Yusuke Eda, Tomoo Ishii

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Akira IkumiDepartment of Orthopaedic Surgery, Tsukuba University Hospital, Tsukuba, Ibaraki 305-8576, Japan.ORCID 0000-0001-6034-1593
Yuichi YoshiiDepartment of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, Ami, Ibaraki 300-0395, Japan.ORCID 0000-0003-1447-4664
Yusuke EdaDepartment of Orthopaedic Surgery, Mito Kyodo General Hospital, Mito, Ibaraki 310-0015, Japan.ORCID 0000-0002-6153-9451
Tomoo IshiiDepartment of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, Ami, Ibaraki 300-0395, Japan.
Tokyo Medical University Ibaraki Medical Center · JPNational Hospital Organization Mito Medical Center · JPUniversity of Tsukuba Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The present study attempted to define the three-dimensional (3D) locations of reference points and standard measures of the distal radius of a normal wrist joint. One hundred wrists from 50 males and 50 females who matched the age distribution (19−95 years old, mean: 56.0 years old) were evaluated. Computed tomography (CT) images of normal wrist joints acquired for comparison with the affected side were used. The absence of a previous history and complaints in the unaffected wrist was confirmed in an interview and with medical records. Three-dimensional images of the distal radius were reconstructed using the data obtained from CT scans. The site at which the major axis of the radial diaphysis contacted the distal radius joint surface was defined as the origin. The 3D coordinates of reference points for the radial styloid process (1), sigmoid notch volar edge (2), and sigmoid notch dorsal edge (3) as well as the barycenter for the joint surface and joint surface area were evaluated. A slope of the line connecting coordinates 1−2 in the coronal plane was evaluated as the 3D radial inclination (3DRI) and that connecting coordinates 2−3 in the sagittal plane as the 3D palmar tilt (3DPT). Each measurement value was compared between males and females. The positions of each reference point from the origin were as follows: (1) 14.2 ± 1.3/12.6 ± 1.1 mm for the distal-palmar-radial position; (2) 19.3 ± 1.3/16.9 ± 1.3 mm for the proximal-palmar-ulnar position; (3) 15.6 ± 1.4/14.1 ± 0.9 mm for the proximal-dorsal-ulnar position; and (barycenter) 4.1 ± 0.7/3.7 ± 0.7 mm for the proximal-volar-ulnar position for males and females, respectively. The areas of the radius articular surface were 429.0 ± 67.9/347.6 ± 44.6 mm2 for males and females, respectively. The 3DRI and 3DPT were 24.2 ± 4.0/25.7 ± 3.1° and 10.9 ± 5.1/13.2 ± 4.4° for males and females, respectively. Significant differences were observed in all measurement values between males and females (p < 0.01). The reference points and measured values obtained in the present study will serve as criteria for identifying the dislocation direction and reduction conditions of distal radius fractures in 3D images.

Indexed as

computed tomographycomputer-aided diagnosisdistal radiusosteosynthesisthree dimensions

Identifiers

PMID36553219
PMCPMC9777835
OpenAlexW4312140481

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.