ArticleDiagnostics (Basel, Switzerland)2022
Accelerating the Laboratory Testing Capacity through Saliva Pooling Prior to Direct RT-qPCR for SARS-CoV-2 Detection.
Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- SARS-CoV-2 RT-LAMP in saliva: enhancing the results via a combination of cooling and specimen dilution procedure.Virusdisease · 2024Article
- Development and validation of cost-effective SYBR Green-based RT-qPCR and its evaluation in a sample pooling strategy for detecting SARS-CoV-2 infection in the Indonesian setting.Scientific reports · 2024Article
- Optimization and application of digital droplet PCR for the detection of SARS-CoV-2 in saliva specimen using commercially available kit.Biology methods & protocols · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The testing capacity of the laboratory is paramount for better control of the pandemic caused by SARS-CoV-2. The pooling method is promising to increase testing capacity, and the use of direct NAAT-based detection of SARS-CoV-2 on a non-invasive specimen such as saliva will ultimately accelerate the testing capacity. This study aims to validate the pooling-of-four method to quadruple the testing capacity using RNA-extraction-free saliva specimens. In addition, we intend to investigate the preferable stage of pooling, including pre- or post-heating. The compatibility of this approach was also tested on five commercial kits. Saliva specimens stored at -80 °C for several months were proven viable and were used for various tests in this study. Our findings revealed that pooling-of-four specimens had an overall agreement rate of 98.18% with their individual testing. Moreover, we proved that the pooling procedure could be conducted either pre- or post-heating, with no discordance and no significant difference in Ct values generated. When compared to other commercial detection kits, it demonstrated an overall agreement greater than 85%, which exhibits broad compatibility and ensures easy adaptability in clinical settings. This method has been proven reliable and increases the testing capacity up to fourfold.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.