Evidence map›Paper›PMID 36553122›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Clinical Evaluation of the ButterfLife Device for Simultaneous Multiparameter Telemonitoring in Hospital and Home Settings.

Francesco Salton, Stefano Kette, Paola Confalonieri, Sergio Fonda, Selene Lerda, Michael Hughes, Marco Confalonieri, Barbara Ruaro

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Francesco SaltonPulmonology Unit, Department of Medical Surgical and Health Sciences, University Hospital of Cattinara, University of Trieste, 34149 Trieste, Italy.ORCID 0000-0002-0864-9766
Stefano KettePulmonology Unit, Department of Medical Surgical and Health Sciences, University Hospital of Cattinara, University of Trieste, 34149 Trieste, Italy.
Paola ConfalonieriPulmonology Unit, Department of Medical Surgical and Health Sciences, University Hospital of Cattinara, University of Trieste, 34149 Trieste, Italy.ORCID 0000-0002-7284-5016
Sergio FondaDepartment of Biomedical Sciences, University of Modena and Reggio Emilia, 41121 Modena, Italy.
Selene Lerda24ORE Business School, Via Monte Rosa, 91, 20149 Milan, Italy.
Michael HughesDivision of Musculoskeletal and Dermatological Sciences, Faculty of Biology, Medicine and Health, The University of Manchester & Salford Royal NHS Foundation Trust, Manchester M6 8HD, UK.
Marco ConfalonieriPulmonology Unit, Department of Medical Surgical and Health Sciences, University Hospital of Cattinara, University of Trieste, 34149 Trieste, Italy.ORCID 0000-0002-4791-768X
Barbara RuaroPulmonology Unit, Department of Medical Surgical and Health Sciences, University Hospital of Cattinara, University of Trieste, 34149 Trieste, Italy.ORCID 0000-0001-8990-859X
University of Trieste · ITSalford Royal NHS Foundation Trust · GBUniversity of Modena and Reggio Emilia · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We conducted a two-phase study to test the reliability and usability of an all-in-one artificial intelligence-based device (ButterfLife), which allows simultaneous monitoring of five vital signs. The first phase of the study aimed to test the agreement between measurements performed with ButterfLife vs. standard of care (SoC) in 42 hospitalized patients affected by acute respiratory failure. In this setting, the greatest discordance between ButterfLife and SoC was in respiratory rate (mean difference -4.69 bpm). Significantly close correlations were observed for all parameters except diastolic blood pressure and oxygen saturation (Spearman's Rho -0.18 mmHg;

Indexed as

artificial intelligenceButterfLifeECGphotoplethysmographytelehealthtelemedicinevital parameters

Identifiers

PMID36553122
PMCPMC9777180
OpenAlexW4312126341

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.