Evidence map›Paper›PMID 36553118›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Inter- and Intra-Observer Agreement When Using a Diagnostic Labeling Scheme for Annotating Findings on Chest X-rays-An Early Step in the Development of a Deep Learning-Based Decision Support System.

Dana Li, Lea Marie Pehrson, Lea Tøttrup, Marco Fraccaro, Rasmus Bonnevie, Jakob Thrane, Peter Jagd Sørensen, Alexander Rykkje, Tobias Thostrup Andersen, Henrik Steglich-Arnholm and 6 more

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

Dana LiDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.
Lea Marie PehrsonDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.
Lea TøttrupUnumed Aps, 1055 Copenhagen, Denmark.
Marco FraccaroUnumed Aps, 1055 Copenhagen, Denmark.
Rasmus BonnevieUnumed Aps, 1055 Copenhagen, Denmark.
Jakob ThraneUnumed Aps, 1055 Copenhagen, Denmark.
Peter Jagd SørensenDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.ORCID 0000-0003-4998-8032
Alexander RykkjeDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.
Tobias Thostrup AndersenDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.ORCID 0000-0002-1672-2927
Henrik Steglich-ArnholmDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.
Dorte Marianne Rohde StærkDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.ORCID 0000-0002-0807-6339
Lotte BorgwardtDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.
Kristoffer Lindskov HansenDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.
Sune DarknerDepartment of Computer Science, University of Copenhagen, 2100 Copenhagen, Denmark.
Jonathan Frederik CarlsenDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.ORCID 0000-0002-6724-7281
Michael Bachmann NielsenDepartment of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.ORCID 0000-0002-9380-1688

Funding

Innovation Fund Denmark 0176-00013B
6 · The paper itself

Abstract

Consistent annotation of data is a prerequisite for the successful training and testing of artificial intelligence-based decision support systems in radiology. This can be obtained by standardizing terminology when annotating diagnostic images. The purpose of this study was to evaluate the annotation consistency among radiologists when using a novel diagnostic labeling scheme for chest X-rays. Six radiologists with experience ranging from one to sixteen years, annotated a set of 100 fully anonymized chest X-rays. The blinded radiologists annotated on two separate occasions. Statistical analyses were done using Randolph's kappa and PABAK, and the proportions of specific agreements were calculated. Fair-to-excellent agreement was found for all labels among the annotators (Randolph's Kappa, 0.40-0.99). The PABAK ranged from 0.12 to 1 for the two-reader inter-rater agreement and 0.26 to 1 for the intra-rater agreement. Descriptive and broad labels achieved the highest proportion of positive agreement in both the inter- and intra-reader analyses. Annotating findings with specific, interpretive labels were found to be difficult for less experienced radiologists. Annotating images with descriptive labels may increase agreement between radiologists with different experience levels compared to annotation with interpretive labels.

Indexed as

artificial intelligencechest X-raydiagnostic schemeimage annotationinter-raterintra-raterontologyradiologists

Identifiers

PMID36553118
PMCPMC9776917

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked