Evidence map›Paper›PMID 36553020›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Contrast-Enhanced Ultrasonography with Arrival Time Parametric Imaging as a Non-Invasive Diagnostic Tool for Liver Cirrhosis.

Raluca Lupușoru, Ioan Sporea, Iulia Rațiu, Diana Lungeanu, Alina Popescu, Mirela Dănilă, Ruxandra Mare, Luciana Marc, Andrada Lascău, Tudor Voicu Moga and 3 more

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Dendrobium officinale Polysaccharides Protected against CClChinese journal of integrative medicine · 2026
    Article
  2. Article
  3. Arrival-Time Parametric Imaging in Contrast-Enhanced Ultrasound for Thyroid Nodule Differentiation.Medical science monitor : international medical journal of experimental and clinical research · 2024
    Article
  4. Enhanced Diagnostic Imaging: Arrival-Time Parametric Imaging in Contrast-Enhanced Ultrasound for Multi-Organ Assessment.Medical science monitor : international medical journal of experimental and clinical research · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 3 institutions in 1 country.

Raluca LupușoruCenter for Modeling Biological Systems and Data Analysis, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.ORCID 0000-0002-7405-4779
Ioan SporeaAdvanced Regional Research Center in Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.
Iulia RațiuDepartment of Internal Medicine II, Division of Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.ORCID 0000-0002-5622-9926
Diana LungeanuCenter for Modeling Biological Systems and Data Analysis, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.ORCID 0000-0002-0274-1377
Alina PopescuDepartment of Internal Medicine II, Division of Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.ORCID 0000-0002-9141-7228
Mirela DănilăDepartment of Internal Medicine II, Division of Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.
Ruxandra MareDepartment of Internal Medicine II, Division of Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.ORCID 0000-0002-6777-5949
Luciana MarcDepartment of Internal Medicine II, Division of Nephrology, "Victor Babeș" University of Medicine and Pharmacy, 300041 Timisoara, Romania.
Andrada LascăuDiscipline of Accounting and Information System, Faculty of Economics and Business Administration, West University of Timisoara, 300115 Timisoara, Romania.
Tudor Voicu MogaDepartment of Internal Medicine II, Division of Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.ORCID 0000-0002-8978-1856
Felix BendeDepartment of Internal Medicine II, Division of Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.ORCID 0000-0003-3820-7325
Ana-Maria GhiuchiciDepartment of Internal Medicine II, Division of Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.
Roxana ȘirliDepartment of Internal Medicine II, Division of Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.ORCID 0000-0002-0179-1014
Spitalul Clinic Judeţean de Urgenţă "Pius Brînzeu" Timişoara · ROVictor Babeș University of Medicine and Pharmacy Timișoara · ROWest University of Timişoara · RO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Liver biopsy is the gold standard method for staging liver fibrosis, but it is an invasive procedure that is associated with some complications. There are also non-invasive techniques for assessing liver fibrosis, such as elastography and biological tests, but these techniques can fail in detection or generate false measurements depending on the subject’s condition. This study aimed to determine whether liver fibrosis can be evaluated using contrast-enhanced ultrasonography with arrival time parametric imaging using the ultrasound machine’s parametric image software, the method being called (CEUS-PAT). CEUS-PAT was performed on each subject using SonoVue as a contrast agent, and images showing liver parenchyma and the right kidney on a single screen were used for analysis in parametric imaging, which was performed using the proprietary software of the ultrasound system. The ratio between the kidney and liver arrival times was calculated. The study included 64 predominantly male (56.3%) subjects, 37 cirrhotic patients, and 27 healthy volunteers, with a mean age of 58.98 ± 8.90 years. Significant differences were found between the liver cirrhosis and healthy groups regarding CEUS-PAT, 0.83 ± 0.09 vs. 0.49 ± 0.11, p < 0.0001. The correlation between CEUS-PAT and VCTE was r = 0.81. The optimal cut-off value for detecting liver cirrhosis was >0.7, with an AUC of 0.98, p < 0.001, Se = 89.19%, Sp = 100%, PPV = 100%, and NPV = 87.1%. We demonstrate that CEUS-PAT achieves excellent performance in diagnosing liver cirrhosis and is a fast method for diagnosing liver cirrhosis that can even be applied in situations where the use of other methods is excluded.

Indexed as

AtPI/arrival time parametric imagingCEUSliver cirrhosisVCTE

Identifiers

PMID36553020
PMCPMC9777167
OpenAlexW4310611533

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.