ArticleBiomedicines2022
Determination of the Assigned Values of Blood Cells by an Impedance Method for Hematological Reference Samples Used in Hematology External Quality Assessment (EQA) Programs.
Article in Biomedicines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Enhanced stability of simulated leukocytes for hematology internal quality control samples: A material improvement.PloS one · 2025Article
- The Impact of Latihan Pasrah Diri / Self Surrender Practice (LPD) in Sleep Quality and Inflammatory Markers in Diabetes Mellitus Type 2 Patients Without Depression: A Randomized Controlled Trial.Integrative medicine (Encinitas, Calif.) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The research into and production of hematological reference samples used to implement an external quality assessment (EQA) to check the quality of hematology tests are necessary for hematology laboratories in Vietnam. In this research, the study team determined the assessment values of blood cell count (human RBCs, pseudo-leucocytes, and pseudo-platelets) by the impedance method used in hematology EQA programs. The hematological reference samples were controlled at three concentration levels: low, normal, and high. Determination of the assigned value (mean ± 2SD) was performed for the following hematology analyzer series by impedance method: ABX Micros 60, Celldyn 1700, and Mindray BC 2000. Each device was sent to 10 different laboratories for evaluation. Research results for assigned values of each model (ABX Micros 60, Celldyn 1700, and Mindray BC 2000) were determined at the three concentrations. For the ABX Micros 60 and Celldyn 1700 series, 80% of laboratories had analytical results within assigned values. For the Mindray BC 2000 series, 100% of laboratories had analytical results within assigned values. The measurement results for the number of human RBCs, pseudo-leucocytes, and pseudo-platelets on each analyzer were similar between the 10 laboratories; the results of the three hematology analyzer series using the impedance method were different and the difference was statistically significant (p < 0.05). Thus, hematological reference samples for measuring the number of blood cells meeting the standards so that they can evaluate the results of laboratories using the impedance method: ABX, Celldyn 1700, Mindray BC 2000.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.